Literature DB >> 17041083

Which orthodontic archwire sequence? A randomized clinical trial.

Na Mandall1, C Lowe, Hv Worthington, J Sandler, S Derwent, M Abdi-Oskouei, S Ward.   

Abstract

The aim of this study was to compare three orthodontic archwire sequences. One hundred and fifty-four 10- to 17-year-old patients were treated in three centres and randomly allocated to one of three groups: A = 0.016-inch nickel titanium (NiTi), 0.018 x 0.025-inch NiTi, and 0.019 x 0.025-inch stainless steel (SS); B = 0.016-inch NiTi, 0.016-inch SS, 0.020-inch SS, and 0.019 x 0.025-inch SS; and C = 0.016 x 0.022-inch copper (Cu) NiTi, 0.019 x 0.025-inch CuNiTi, and 0.019 x 0.025-inch SS. At each archwire change and for each arch, the patients completed discomfort scores on a seven-point Likert scale at 4 hours, 24 hours, 3 days, and 1 week. Time in days and the number of visits taken to reach a 0.019 x 0.025-inch SS working archwires were calculated. A periapical radiograph of the upper left central incisor was taken at the start of the treatment and after placement of the 0.019 x 0.025-inch SS wire so root resorption could be assessed. There were no statistically significant differences between archwire sequences A, B, or C for patient discomfort (P > 0.05) or root resorption (P = 0.58). The number of visits required to reach the working archwire was greater for sequence B than for A (P = 0.012) but this could not be explained by the increased number of archwires used in sequence B.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17041083     DOI: 10.1093/ejo/cjl030

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  11 in total

Review 1.  Root Resorption in Orthodontics.

Authors:  Furkan Dindaroğlu; Servet Doğan
Journal:  Turk J Orthod       Date:  2016-12-01

Review 2.  Which Orthodontic Wire and Working Sequence Should be Preferred for Alignment Phase? A Review.

Authors:  Sedef Sera Hepdarcan; R Burcu Nur Yılmaz; Didem Nalbantgil
Journal:  Turk J Orthod       Date:  2016-06-01

3.  Alignment efficiency of superelastic coaxial nickel-titanium vs superelastic single-stranded nickel-titanium in relieving mandibular anterior crowding: a randomized controlled prospective study.

Authors:  Biju Sebastian
Journal:  Angle Orthod       Date:  2011-10-19       Impact factor: 2.079

4.  Bidimensional techniques for stronger anterior torque control in extraction cases: a combined clinical and typodont study.

Authors:  Yu Li; Na Tang; Zhenrui Xu; Xiaoxia Feng; Liang Yang; Zhihe Zhao
Journal:  Angle Orthod       Date:  2011-12-08       Impact factor: 2.079

5.  Perception of Iraqi Orthodontists and Patients toward Accelerated Orthodontics.

Authors:  Ali M Al-Attar; Samher Al-Shaham; Mushriq Abid
Journal:  Int J Dent       Date:  2021-04-29

Review 6.  Initial arch wires used in orthodontic treatment with fixed appliances.

Authors:  Yan Wang; Chang Liu; Fan Jian; Grant T McIntyre; Declan T Millett; Joy Hickman; Wenli Lai
Journal:  Cochrane Database Syst Rev       Date:  2018-07-31

7.  Clinical Efficiency of Two Sequences of Orthodontic Wires to Correct Crowding of the Lower Anterior Teeth.

Authors:  Cláudia Maria de Castro Serafim; Júlio de Araújo Gurgel; Carollyne Mota Tiago; Rudys Rodolfo de Jesus Tavarez; Etevaldo Matos Maia Filho
Journal:  ScientificWorldJournal       Date:  2015-06-14

8.  Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial.

Authors:  Burcu Aydın; Neslihan Ebru Şenışık; Özgür Koşkan
Journal:  Korean J Orthod       Date:  2018-04-20       Impact factor: 1.372

9.  En-masse retraction with a preformed nickel-titanium and stainless steel archwire assembly and temporary skeletal anchorage devices without posterior bonding.

Authors:  Jeong-Hyun Jee; Hyo-Won Ahn; Kyung-Won Seo; Seong-Hun Kim; Yoon-Ah Kook; Kyu-Rhim Chung; Gerald Nelson
Journal:  Korean J Orthod       Date:  2014-09-25       Impact factor: 1.372

10.  Supplemental vibrational force does not reduce pain experience during initial alignment with fixed orthodontic appliances: a multicenter randomized clinical trial.

Authors:  Neil R Woodhouse; Andrew T DiBiase; Spyridon N Papageorgiou; Nicola Johnson; Carmel Slipper; James Grant; Maryam Alsaleh; Martyn T Cobourne
Journal:  Sci Rep       Date:  2015-11-27       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.