Literature DB >> 17038945

Use of heparin-coated stents in neurovascular interventional procedures: preliminary experience with 10 patients.

Richard J Parkinson1, Christopher P Demers, Joseph G Adel, Elad I Levy, Eric Sauvageau, Ricardo A Hanel, Ali Shaibani, Lee R Guterman, L Nelson Hopkins, H Hunt Batjer, Bernard R Bendok.   

Abstract

OBJECTIVE: Currently, there is minimal published data on the use of heparin-coated stents in the neurovasculature; however, these stents have a proven clinical record in the treatment of coronary disease. This article details our experience with the safety and technical aspects of stent deployment in the first 10 patients who had heparin-coated stents placed in the intracranial and cervical vasculature and the preliminary follow-up in most cases.
METHODS: We retrospectively reviewed the clinical history, intra- and periprocedural data, and imaging for the patients who received heparin-coated stents in the cervical and intracranial vasculature for cerebrovascular disease between October 2002 and October 2003.
RESULTS: Thirteen heparin-coated stents were placed in 10 patients. Seven out of the 10 patients had heparin-coated stents placed in the posterior circulation; the remaining three patients had stents placed in the anterior circulation. Four patients had stents placed intracranially. There was no acute or subacute in-stent thrombosis and no procedure-related complications. Follow-up was performed on most patients, with no clinical symptoms attributable to restenosis in any patient.
CONCLUSION: This small series suggests that heparin-coated stents are safe for use in the treatment of cervical and intracranial atherosclerotic disease. Longer-term follow-up is needed to study the heparin coating effect on in-stent restenosis rates and to assess the long-term durability and clinical efficacy of this stent. The use of drug-coated stents in the cerebrovascular circulation is an area that warrants further investigation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17038945     DOI: 10.1227/01.NEU.0000232836.66310.46

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  4 in total

Review 1.  Molecular engineering of glycosaminoglycan chemistry for biomolecule delivery.

Authors:  Tobias Miller; Melissa C Goude; Todd C McDevitt; Johnna S Temenoff
Journal:  Acta Biomater       Date:  2013-10-09       Impact factor: 8.947

2.  On the potential for fibronectin/phosphorylcholine coatings on PTFE substrates to jointly modulate endothelial cell adhesion and hemocompatibility properties.

Authors:  Vanessa Montaño-Machado; Pascale Chevallier; Diego Mantovani; Emmanuel Pauthe
Journal:  Biomatter       Date:  2015

Review 3.  Anti-thrombogenic coatings for devices in neurointerventional surgery: Case report and review of the literature.

Authors:  Hans Henkes; Pervinder Bhogal; Marta Aguilar Pérez; Tim Lenz-Habijan; Catrin Bannewitz; Marcus Peters; Christina Sengstock; Oliver Ganslandt; Pedro Lylyk; Hermann Monstadt
Journal:  Interv Neuroradiol       Date:  2019-06-27       Impact factor: 1.610

4.  Influence of spacer length on heparin coupling efficiency and fibrinogen adsorption of modified titanium surfaces.

Authors:  David Tebbe; Roger Thull; Uwe Gbureck
Journal:  Biomed Eng Online       Date:  2007-07-17       Impact factor: 2.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.