Brain and whole body distribution of N-isopropyl-4-iodoamphetamine (I-123) in humans: comparison of radiopharmaceuticals marketed by different companies in Japan.

Hiroshi Ito1, Tachio Sato, Hayato Odagiri, Kentaro Inoue, Miho Shidahara, Tetsuya Suhara, Jun Hatazawa, Hiroshi Fukuda.   

Abstract

OBJECTIVE: Iodine-123 (123I)-labeled N-isopropyl-4-iodoamphetamine (IMP) has been used as a cerebral blood flow (CBF) tracer for single-photon emission computed tomography (SPECT). An autoradiographic (ARG) method has been developed for the quantitation of CBF by IMP and SPECT. Two IMPs (IMPA and IMPB) produced by different radiopharmaceutical companies are marketed in Japan. In the present study, whole-body distributions including brain and blood of the two IMPs were compared in the same human subjects.
METHODS: Two brain SPECT studies using IMPA or IMPB were performed on separate days in six young healthy men. Whole-body scans were also obtained with a large field-of-view single-head gamma camera. One-point arterial blood sampling was performed at 10 min after injection of IMP to measure both the radioactivity concentrations of whole blood and of octanol-extracted components.
RESULTS: No significant differences between the two tracers were observed in body distribution, tracer kinetics in brain, or regional distribution in brain. However, the octanol extraction fraction in blood was significantly different between the two tracers. Radiochemical purity was slightly but significantly different between the tracers.
CONCLUSIONS: In the ARG method, arterial input function is determined by calibration of a standard input function with the radioactivity concentration of arterial whole blood. Because the standard input function in the ARG method was obtained using IMPA, the standard input function obtained for IMPB should be used when CBF is calculated by the ARG method with IMPB.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17037282     DOI: 10.1007/BF02987259

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  3 in total

1.  Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging.

Authors:  Navid Zeraatkar; Kesava S Kalluri; Benjamin Auer; Arda Konik; Timothy J Fromme; Lars R Furenlid; Phillip H Kuo; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 10.048

2.  Cerebral SPECT imaging with different acquisition schemes using varying levels of multiplexing versus sensitivity in an adaptive multi-pinhole brain-dedicated scanner.

Authors:  Navid Zeraatkar; Kesava S Kalluri; Benjamin Auer; Micaehla May; R Garrett Richards; Lars R Furenlid; Phillip H Kuo; Michael A King
Journal:  Biomed Phys Eng Express       Date:  2021-09-22

3.  Asymptomatic Mild Hyperperfusion for the Prediction of Clinical Outcome in Postoperative Patients After Subarachnoid Hemorrhage.

Authors:  Manabu Nakagawa; Tatsushi Mutoh; Shunsuke Takenaka; Tomoko Mutoh; Tomoko Totsune; Yasuyuki Taki; Tatsuya Ishikawa
Journal:  Med Sci Monit       Date:  2017-01-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.