Literature DB >> 17031817

Detection of hepatic metastases using ferucarbotran-enhanced MR imaging: feasibility and diagnostic accuracy of three-dimensional sensitivity-encoding water-excitation multishot echo-planar sequence (3D-SWEEP).

Kensaku Mori1, Nobuyuki Takahashi, Makiko Hiratsuka, Masanari Shiigai, Manabu Minami, Tatsuya Oda, Nobuhiro Ohkohchi, Yukio Morishita.   

Abstract

PURPOSE: To evaluate the diagnostic accuracy of a ferucarbotran-enhanced three-dimensional sensitivity-encoding water-excitation multishot echo-planar sequence (3D-SWEEP) for detecting hepatic metastases compared to a T2*-weighted fast field-echo (FFE) sequence.
MATERIALS AND METHODS: Twenty-five consecutive patients with hepatic metastases underwent ferucarbotran-enhanced MRI on a 1.5-T unit before hepatic resections. Eighty-two foci of metastases were confirmed by histopathology or intraoperative ultrasonography (US). Signal-intensity decay (SID), tumor-to-liver contrast (TLC), and image quality were compared between T2*-weighted FFE and 3D-SWEEP. Three independent observers reviewed three imaging sets: set 1, without 3D-SWEEP or T2*-weighted FFE; set 2, with T2*-weighted FFE; and set 3, with 3D-SWEEP. The mean values of areas under alternative free response receiver operating characteristic curves (Az) and sensitivities were compared among the three sets.
RESULTS: SID and TLC were significantly greater for 3D-SWEEP than T2*-weighted FFE, although 3D-SWEEP had poorer image quality. The mean Az and sensitivity were significantly greater for set 3 compared to set 1 for detecting overall lesions, and compared to sets 1 and 2 for detecting lesions of 1-2 cm in diameter.
CONCLUSION: Despite relatively prominent artifacts, ferucarbotran-enhanced 3D-SWEEP was more sensitive and accurate than T2*-weighted FFE for detecting hepatic metastases. Copyright (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17031817     DOI: 10.1002/jmri.20755

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  2 in total

1.  Safety margin of radiofrequency ablation for hepatocellular carcinoma: a prospective study using magnetic resonance imaging with superparamagnetic iron oxide.

Authors:  Kuniaki Fukuda; Kensaku Mori; Naoyuki Hasegawa; Katsuhiro Nasu; Kazunori Ishige; Yoshikazu Okamoto; Masanari Shiigai; Masato Abei; Manabu Minami; Ichinosuke Hyodo
Journal:  Jpn J Radiol       Date:  2019-05-17       Impact factor: 2.374

Review 2.  Guidelines for the detection and treatment of liver metastases of colorectal cancer.

Authors:  A Abad; J Figueras; C Valls; A Carrato; F Pardo; E Díaz-Rubio; E Aranda
Journal:  Clin Transl Oncol       Date:  2007-11       Impact factor: 3.405

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.