AIMS: To investigate outcome and complications of implantable cardioverter defibrillators (ICDs) in adults with congenital heart disease (CHD) and to identify predictors of (in-) appropriate shocks. METHODS AND RESULTS: Sixty-four CHD patients >/= 18 years at first ICD implantation [63% tetralogy of Fallot (TOF) and age at implantation 37 +/- 13 years] were identified using the Dutch adult CHD registry and a Belgian tertiary care centre database. Median follow-up duration was 3.7 years. Early complications included pocket haematoma (n = 3), lead failure (n = 2), and pneumothorax (n = 2). Late complications occurred in 11 (17%) patients, including lead failure (n = 6) and and electrical storm (n = 3). Overall, 30 device-related re-interventions were performed in 20 patients (31%), including four premature generator changes and seven lead replacements. Half of the patients received one or more shocks, and 46 shocks in 15 patients (23%) were classified as appropriate. One hundred and sixty shocks in 26 patients (41%) were classified as inappropriate. No predictors of (in-)appropriate shocks were identified, except TOF being associated with less appropriate shocks than patients with other CHD (HR 0.29, P = 0.02). CONCLUSION: The ICD provided effective therapy in a quarter of adults with CHD with low complication rates. The incidence of inappropriate shocks, however, appeared to be excessive and warrants further attention.
AIMS: To investigate outcome and complications of implantable cardioverter defibrillators (ICDs) in adults with congenital heart disease (CHD) and to identify predictors of (in-) appropriate shocks. METHODS AND RESULTS: Sixty-four CHD patients >/= 18 years at first ICD implantation [63% tetralogy of Fallot (TOF) and age at implantation 37 +/- 13 years] were identified using the Dutch adult CHD registry and a Belgian tertiary care centre database. Median follow-up duration was 3.7 years. Early complications included pocket haematoma (n = 3), lead failure (n = 2), and pneumothorax (n = 2). Late complications occurred in 11 (17%) patients, including lead failure (n = 6) and and electrical storm (n = 3). Overall, 30 device-related re-interventions were performed in 20 patients (31%), including four premature generator changes and seven lead replacements. Half of the patients received one or more shocks, and 46 shocks in 15 patients (23%) were classified as appropriate. One hundred and sixty shocks in 26 patients (41%) were classified as inappropriate. No predictors of (in-)appropriate shocks were identified, except TOF being associated with less appropriate shocks than patients with other CHD (HR 0.29, P = 0.02). CONCLUSION: The ICD provided effective therapy in a quarter of adults with CHD with low complication rates. The incidence of inappropriate shocks, however, appeared to be excessive and warrants further attention.
Authors: Timothy Cotts; Paul Khairy; Alexander R Opotowsky; Anitha S John; Anne Marie Valente; Ali N Zaidi; Stephen C Cook; Jamil Aboulhosn; Jennifer Grando Ting; Michelle Gurvitz; Michael J Landzberg; Amy Verstappen; Joseph Kay; Michael Earing; Wayne Franklin; Brian Kogon; Craig S Broberg Journal: Int J Cardiol Date: 2013-12-24 Impact factor: 4.164
Authors: Nicholas H Von Bergen; Dianne L Atkins; Macdonald Dick; David J Bradley; Susan P Etheridge; Elizabeth V Saarel; Peter S Fischbach; Seshadri Balaji; Narayanswami Sreeram; William N Evans; Ian H Law Journal: Pediatr Cardiol Date: 2011-01-06 Impact factor: 1.655