Literature DB >> 17029779

Electrochemical detection of HbA1c, a marker [correction of maker] for diabetes, using a flow immunoassay system.

Tsuyoshi Tanaka1, Shoko Tsukube, Kojiro Izawa, Mina Okochi, Tae-Kyu Lim, Shugo Watanabe, Manabu Harada, Tadashi Matsunaga.   

Abstract

An on-chip electrochemical flow immunoassay system for the detection of hemoglobin A1c (HbA1c) was developed using anti-human hemoglobin (Hb) IgG labeled with ferrocene monocarboxylic acid (Fc-COOH) and boronate-affinity chromatography. An on-chip column packed with boronate-activated agarose beads was used for the separation of HbA1c from both non-glycated Hb and free antibody. Anti-human Hb IgG conjugated to Fc-COOH (Fc-IgG) was used for the electrochemical detection of HbA1c. The assay procedure included immunoreactions with Fc-IgG and HbA1c, separation of immunocomplexes by boronate affinity, and electrochemical detection of Fc-IgG-HbA1c immunocomplexes. The immunoreaction mixtures were injected onto a boronate-affinity column. HbA1c-antibody complexes were then trapped onto the column by the affinity of HbA1c to boronic acid. Subsequently, elution buffer containing sorbitol was applied to elute HbA1c-antibody complexes and a current was detected by applying 600 mV versus Ag/AgCl. The elution signal was an estimation of the HbA1c amount. A linear correlation between the increase of current and HbA1c concentration was obtained up to an HbA1c concentration of 500 microg/ml. The HbA1c flow immunoassay was successfully achieved using hemolysates. This electrochemical flow immunoassay system enabled us to construct a novel point-of-care testing device for the monitoring of glycated proteins including HbA1c.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17029779     DOI: 10.1016/j.bios.2006.09.008

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Emerging trends in optical sensing of glycemic markers for diabetes monitoring.

Authors:  Rishikesh Pandey; Narahara Chari Dingari; Nicolas Spegazzini; Ramachandra R Dasari; Gary L Horowitz; Ishan Barman
Journal:  Trends Analyt Chem       Date:  2015-01-01       Impact factor: 12.296

Review 2.  Current Status of HbA1c Biosensors.

Authors:  Hua Lin; Jun Yi
Journal:  Sensors (Basel)       Date:  2017-08-04       Impact factor: 3.576

Review 3.  Antibody-Electroactive Probe Conjugates Based Electrochemical Immunosensors.

Authors:  Mateusz Kondzior; Iwona Grabowska
Journal:  Sensors (Basel)       Date:  2020-04-03       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.