A computer simulated phantom study of tomotherapy dose optimization based on probability density functions (PDF) and potential errors caused by low reproducibility of PDF.

Ke Sheng1, Jing Cai, James Brookeman, Janelle Molloy, John Christopher, Paul Read.   

Abstract

Lung tumor motion trajectories measured by four-dimensional CT or dynamic MRI can be converted to a probability density function (PDF), which describes the probability of the tumor at a certain position, for PDF based treatment planning. Using this method in simulated sequential tomotherapy, we study the dose reduction of normal tissues and more important, the effect of PDF reproducibility on the accuracy of dosimetry. For these purposes, realistic PDFs were obtained from two dynamic MRI scans of a healthy volunteer within a 2 week interval. The first PDF was accumulated from a 300 s scan and the second PDF was calculated from variable scan times from 5 s (one breathing cycle) to 300 s. Optimized beam fluences based on the second PDF were delivered to the hypothetical gross target volume (GTV) of a lung phantom that moved following the first PDF The reproducibility between two PDFs varied from low (78%) to high (94.8%) when the second scan time increased from 5 s to 300 s. When a highly reproducible PDF was used in optimization, the dose coverage of GTV was maintained; phantom lung receiving 10%-20% prescription dose was reduced by 40%-50% and the mean phantom lung dose was reduced by 9.6%. However, optimization based on PDF with low reproducibility resulted in a 50% underdosed GTV. The dosimetric error increased nearly exponentially as the PDF error increased. Therefore, although the dose of the tumor surrounding tissue can be theoretically reduced by PDF based treatment planning, the reliability and applicability of this method highly depend on if a reproducible PDF exists and is measurable. By correlating the dosimetric error and PDF error together, a useful guideline for PDF data acquisition and patient qualification for PDF based planning can be derived.

Entities:  

Mesh:

Year:  2006        PMID: 17022227     DOI: 10.1118/1.2222331

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Multiple anatomy optimization of accumulated dose.

Authors:  W Tyler Watkins; Joseph A Moore; James Gordon; Geoffrey D Hugo; Jeffrey V Siebers
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

2.  A probability-based multi-cycle sorting method for 4D-MRI: A simulation study.

Authors:  Xiao Liang; Fang-Fang Yin; Yilin Liu; Jing Cai
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

3.  Impact of respiratory motion on worst-case scenario optimized intensity modulated proton therapy for lung cancers.

Authors:  Wei Liu; Zhongxing Liao; Steven E Schild; Zhong Liu; Heng Li; Yupeng Li; Peter C Park; Xiaoqiang Li; Joshua Stoker; Jiajian Shen; Sameer Keole; Aman Anand; Mirek Fatyga; Lei Dong; Narayan Sahoo; Sujay Vora; William Wong; X Ronald Zhu; Martin Bues; Radhe Mohan
Journal:  Pract Radiat Oncol       Date:  2014-09-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.