Micromechanical versus chemical bonding between CoCr alloys and methacrylate resins.

Craig W Barclay1, Donald Spence, William R E Laird, Peter M Marquis, Liam Blunt.   

Abstract

INTRODUCTION: As adhesive systems for bonding to metals have developed in dentistry, considerable importance is attached to the preparation of the metal alloy for both mechanical and chemical bonding. Different grit sizes when sandblasting Cobalt Chromium (CoCr) will provide a different three-dimensional surface for bonding. Previous reports have shown that 4-Methacryloyloxyethyl trimellitic anhydride (4-Meta) resins offer high bond strengths to CoCr alloy, with various surface preparations providing varying bond strengths. The relevance of this to bond strength was assessed.
OBJECTIVES: The aim of the study was to evaluate the importance of grit size of alumina in the preparation of CoCr alloy and to determine the effect on the tensile bond strength of four different acrylic resins to the CoCr alloy.
METHODS: Ten specimens were prepared within each group of four resins. Four grit sizes were assessed, 50, 110, 250 microm, and a range from 180 to 330 microm. The specimens were tested both within one day of production after storing at 37 degrees C in phosphate-buffered saline for seven days and after thermocycling.
RESULTS: Grit size resulted in a change in average contact surface area available for bonding. A significant difference (p < 0.01) existed in bond strengths between each of the materials, but no significant difference (p = 0.0673) was determined when different grit sizes were included. SIGNIFICANCE: It was concluded that grit size determined the available contact surface area of CoCr alloy for bonding but did not determine the bond strength that could be achieved between acrylic resins and CoCr alloy as a result of the poor adaptation of the resin to the complex surface topography.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17022056     DOI: 10.1002/jbm.b.30672

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  2 in total

1.  Effect of different surface treatments and retainer designs on the retention of posterior Pd-Ag porcelain-fused-to-metal resin-bonded fixed partial dentures.

Authors:  Xiwen Chen; Yixin Zhang; Jinru Zhou; Chenfeng Chen; Zhimin Zhu; Lei Li
Journal:  Exp Ther Med       Date:  2017-12-14       Impact factor: 2.447

2.  Effect of Fiber Laser Irradiation on the Shear Bond Strength between Acrylic Resin and Titanium.

Authors:  Fatih Mehmet Korkmaz; Selin Aycan
Journal:  Scanning       Date:  2019-09-03       Impact factor: 1.932

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.