Literature DB >> 17019856

Simulation of intramuscular EMG signals detected using implantable myoelectric sensors (IMES).

Madeleine M Lowery1, Richard F ff Weir, Todd A Kuiken.   

Abstract

The purpose of this study was to test the feasibility of recording independent electromyographic (EMG) signals from the forearm using implantable myoelectric sensors (IMES), for myoelectric prosthetic control. Action potentials were simulated using two different volume conductor models: a finite-element (FE) model that was used to explore the influence of the electrical properties of the surrounding inhomogeneous tissues and an analytical infinite volume conductor model that was used to estimate the approximate detection volume of the implanted sensors. Action potential amplitude increased progressively as conducting electrodes, the ceramic electrode casing and high resistivity encapsulation tissue were added to the model. For the muscle fiber locations examined, the mean increase in EMG root mean square amplitude when the full range of material properties was included in the model was 18.2% (+/-8.1%). Changing the orientation of the electrode with respect to the fiber direction altered the shape of the electrode detection volume and reduced the electrode selectivity. The estimated detection radius of the IMES electrode, assuming a cylindrical muscle cross section, was 4.8, 6.2, and 7.5 mm for electrode orientations of 0 degree, 22.5 degrees, and 45 degrees with respect to the muscle fiber direction.

Mesh:

Year:  2006        PMID: 17019856     DOI: 10.1109/TBME.2006.881774

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  12 in total

1.  A muscle architecture model offering control over motor unit fiber density distributions.

Authors:  Javier Navallas; Armando Malanda; Luis Gila; Javier Rodríguez; Ignacio Rodríguez
Journal:  Med Biol Eng Comput       Date:  2010-06-10       Impact factor: 2.602

2.  Improved myoelectric prosthesis control using targeted reinnervation surgery: a case series.

Authors:  Laura A Miller; Kathy A Stubblefield; Robert D Lipschutz; Blair A Lock; Todd A Kuiken
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2008-02       Impact factor: 3.802

3.  Comparative evaluation of motor unit architecture models.

Authors:  Javier Navallas; Armando Malanda; Luis Gila; Javier Rodriguez; Ignacio Rodriguez
Journal:  Med Biol Eng Comput       Date:  2009-08-25       Impact factor: 2.602

4.  Dexterous control of a prosthetic hand using fine-wire intramuscular electrodes in targeted extrinsic muscles.

Authors:  Christian Cipriani; Jacob L Segil; J Alex Birdwell; Richard F ff Weir
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2014-01-21       Impact factor: 3.802

5.  Contraction level, but not force direction or wrist position, affects the spatial distribution of motor unit recruitment in the biceps brachii muscle.

Authors:  Daniele Borzelli; Marco Gazzoni; Alberto Botter; Laura Gastaldi; Andrea d'Avella; Taian M Vieira
Journal:  Eur J Appl Physiol       Date:  2020-02-19       Impact factor: 3.078

Review 6.  Targeted Muscle Reinnervation to Improve Pain, Prosthetic Tolerance, and Bioprosthetic Outcomes in the Amputee.

Authors:  J Byers Bowen; Corinne E Wee; Jaclyn Kalik; Ian L Valerio
Journal:  Adv Wound Care (New Rochelle)       Date:  2017-08-01       Impact factor: 4.730

7.  A Novel Validation Approach for High-Density Surface EMG Decomposition in Motor Neuron Disease.

Authors:  Maoqi Chen; Xu Zhang; Ping Zhou
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2018-06       Impact factor: 3.802

8.  Maintenance of standing posture during multi-directional leaning demands the recruitment of task-specific motor units in the ankle plantarflexors.

Authors:  Joshua W Cohen; Taian Vieira; Tanya D Ivanova; Giacinto L Cerone; S Jayne Garland
Journal:  Exp Brain Res       Date:  2021-06-30       Impact factor: 1.972

9.  Implantable myoelectric sensors (IMESs) for intramuscular electromyogram recording.

Authors:  Richard F ff Weir; Phil R Troyk; Glen A DeMichele; Douglas A Kerns; Jack F Schorsch; Huub Maas
Journal:  IEEE Trans Biomed Eng       Date:  2009-01       Impact factor: 4.538

10.  First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic hand.

Authors:  Paul F Pasquina; Melissa Evangelista; A J Carvalho; Joseph Lockhart; Sarah Griffin; George Nanos; Patricia McKay; Morten Hansen; Derek Ipsen; James Vandersea; Josef Butkus; Matthew Miller; Ian Murphy; David Hankin
Journal:  J Neurosci Methods       Date:  2014-08-04       Impact factor: 2.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.