Literature DB >> 17016216

Hydroxyapatite-coated femoral components: 15-year minimum followup.

William N Capello1, James A D'Antonio, William L Jaffe, Rudolph G Geesink, Michael T Manley, Judy R Feinberg.   

Abstract

Hydroxyapatite-coated femoral components were introduced to enhance fixation, but concerns were raised about whether the coating would be maintained over time. We therefore determined the long-term clinical and radiographic results of a proximally hydroxyapatite-coated femoral component and compared the mechanical failure rate to other fixation methods at similar lengths of followup. The study group, culled from a large, multicenter prospective study population, consisted of 146 patients (166 hips) with followup of 15 to 18 years. Average age at time of the index procedure was 51 years, and the most common diagnoses were osteoarthritis (71%) and osteonecrosis (11%). Average Harris hip scores were 42.7 preoperatively and 91.5 at most recent followup. Radiographically, one stem showed stable fibrous fixation, and all other unrevised stems were bony stable. Of 13 stem revisions in the study population, only one stem has been revised for aseptic loosening. Forty-nine percent of hips have an osteolytic lesion in proximal areas of Gruen Zones 1, 7, 8, or 14 only. Both the femoral aseptic revision and mechanical failure rates are 0.6% at 15-year minimum followup. The data demonstrate excellent long-term survivorship of this hydroxyapatite-coated femoral component used in a relatively young patient group.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17016216     DOI: 10.1097/01.blo.0000246534.44629.b2

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  16 in total

1.  Enhanced osteointegration of orthopaedic implant gradient coating composed of bioactive glass and nanohydroxyapatite.

Authors:  Xin-Hui Xie; Xiao-Wei Yu; Shao-Xian Zeng; Rui-Lin Du; Yu-Huai Hu; Zhen Yuan; Er-Yi Lu; Ke-Rong Dai; Ting-Ting Tang
Journal:  J Mater Sci Mater Med       Date:  2010-04-09       Impact factor: 3.896

2.  Stable fixation of short-stem femoral implants in patients 70 years and older.

Authors:  Ronak M Patel; Matthew C Smith; Chase C Woodward; S David Stulberg
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

3.  Increased risk of periprosthetic femur fractures associated with a unique cementless stem design.

Authors:  Chad D Watts; Matthew P Abdel; David G Lewallen; Daniel J Berry; Arlen D Hanssen
Journal:  Clin Orthop Relat Res       Date:  2014-12-12       Impact factor: 4.176

4.  Comparison of the 5-Year Outcomes Between Standard and Short Fit-and-Fill Stems in Japanese Populations.

Authors:  Suguru Kato; Masahiko Nozawa; Sungon Kim; Yuko Sakamoto; Hironori Ochi; Muneaki Ishijima
Journal:  Arthroplast Today       Date:  2022-04-25

5.  Uncemented custom femoral components in hip arthroplasty. A prospective clinical study of 191 hips followed for at least 7 years.

Authors:  Pål Benum; Arild Aamodt
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

6.  Ultrashort versus Conventional Anatomic Cementless Femoral Stems in the Same Patients Younger Than 55 Years.

Authors:  Young-Hoo Kim; Jang-Won Park; Jun-Shik Kim
Journal:  Clin Orthop Relat Res       Date:  2016-06-03       Impact factor: 4.176

7.  Short neck-preserving femoral stem for total hip arthroplasty: medium-term results of a 68-case series.

Authors:  Marta Del Río-Arteaga; Jesús Payo-Ollero; Mercedes Vallejo; David Serrano-Toledano; Boris García-Benítez; Juan Ribera
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-24       Impact factor: 2.928

8.  Cementless hydroxyapatite coated hip prostheses.

Authors:  Antonio Herrera; Jesús Mateo; Jorge Gil-Albarova; Antonio Lobo-Escolar; Elena Ibarz; Sergio Gabarre; Yolanda Más; Luis Gracia
Journal:  Biomed Res Int       Date:  2015-02-23       Impact factor: 3.411

9.  Finite element analysis of cementless femoral stems based on mid- and long-term radiological evaluation.

Authors:  Kanehiro Matsuyama; Yasuhiro Ishidou; Yong-Ming Guo; Hironori Kakoi; Takao Setoguchi; Satoshi Nagano; Ichiro Kawamura; Shingo Maeda; Setsuro Komiya
Journal:  BMC Musculoskelet Disord       Date:  2016-09-19       Impact factor: 2.362

10.  Effect of local TGF-beta1 and IGF-1 release on implant fixation: comparison with hydroxyapatite coating: a paired study in dogs.

Authors:  Anders Lamberg; Joan E Bechtold; Jørgen Baas; Kjeld Søballe; Brian Elmengaard
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.