Literature DB >> 17015404

Diagnosis of aortic valvular stenosis by multislice cardiac computed tomography.

Erik Bouvier1, Damien Logeart, Jean-Louis Sablayrolles, Jacques Feignoux, Claude Scheublé, Thierry Touche, Gabriel Thabut, Alain Cohen-Solal.   

Abstract

AIMS: Current improvements in spatial, temporal, and contrast resolution of multislice computed tomography (CT) could be useful in the assessment of valvular diseases. We evaluated the diagnostic accuracy of multislice CT for the identification and quantification of aortic valvular stenosis (AS), compared with echography. METHODS AND
RESULTS: Consecutive patients, referred for coronary CT, were evaluated for AS, by the use of standard electrocardiography-gated 16-slice CT protocol. Multiplanar reformat was applied to systolic phases of the cardiac cycle, with projection on thick slices for measuring the aortic valvular area (AVA). CT results were compared with echocardiographic-based measurement of the AVA. Among 107 enrolled patients, CT analysis of the AVA was feasible in 103. Among the 30 patients with AS, Bland-Altman analysis showed good agreement between the two methods [mean difference -7 mm(2) (-40-25 mm(2))].
CONCLUSION: CT analysis of aortic valve is feasible in most cases and allows for reliable diagnosis and quantification of AS.

Entities:  

Mesh:

Year:  2006        PMID: 17015404     DOI: 10.1093/eurheartj/ehl273

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  13 in total

1.  Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography.

Authors:  Kian Keong Poh; Robert A Levine; Jorge Solis; Liang Shen; Mary Flaherty; Yue-Jian Kang; J Luis Guerrero; Judy Hung
Journal:  Eur Heart J       Date:  2008-02-09       Impact factor: 29.983

2.  The utility of computed tomography in the context of aortic valve disease.

Authors:  Gudrun M Feuchtner
Journal:  Int J Cardiovasc Imaging       Date:  2009-05-26       Impact factor: 2.357

3.  Aortic valve area assessed with 320-detector computed tomography: comparison with transthoracic echocardiography.

Authors:  Linnea Hornbech Larsen; Klaus Fuglsang Kofoed; Helle Gervig Carstensen; Mads Rams Mejdahl; Mads Jønsson Andersen; Jesper Kjaergaard; Olav Wendelboe Nielsen; Lars Køber; Rasmus Møgelvang; Christian Hassager
Journal:  Int J Cardiovasc Imaging       Date:  2013-10-15       Impact factor: 2.357

4.  Comparison of postprocessing techniques for the detection of perfusion defects by cardiac computed tomography in patients presenting with acute ST-segment elevation myocardial infarction.

Authors:  Ian S Rogers; Ricardo C Cury; Ron Blankstein; Michael D Shapiro; Koen Nieman; Udo Hoffmann; Thomas J Brady; Suhny Abbara
Journal:  J Cardiovasc Comput Tomogr       Date:  2010-04-11

5.  Comprehensive evaluation of preoperative patients with aortic valve stenosis: usefulness of cardiac multidetector computed tomography.

Authors:  Jean-Pierre Laissy; David Messika-Zeitoun; Jean-Michel Serfaty; Vincent Sebban; Elisabeth Schouman-Claeys; Bernard Iung; Alec Vahanian
Journal:  Heart       Date:  2007-05-04       Impact factor: 5.994

6.  Aortic valve area: meta-analysis of diagnostic performance of multi-detector computed tomography for aortic valve area measurements as compared to transthoracic echocardiography.

Authors:  Rajnil G Shah; Gian M Novaro; Rodolfo J Blandon; Mitchell S Whiteman; Craig R Asher; Jacobo Kirsch
Journal:  Int J Cardiovasc Imaging       Date:  2009-05-07       Impact factor: 2.357

Review 7.  Evaluation of the aortic and mitral valves with cardiac computed tomography and cardiac magnetic resonance imaging.

Authors:  Sung Min Ko; Meong Gun Song; Hweung Kon Hwang
Journal:  Int J Cardiovasc Imaging       Date:  2012-11-09       Impact factor: 2.357

Review 8.  Applications of Cardiac Computed Tomography in the Cardio-Oncology Population.

Authors:  Michael E Layoun; Eric H Yang; Joerg Herrmann; Cezar A Iliescu; Juan C Lopez-Mattei; Kostas Marmagkiolis; Matthew J Budoff; Maros Ferencik
Journal:  Curr Treat Options Oncol       Date:  2019-05-06

9.  Automated detection of healthy and diseased aortae from images obtained by contrast-enhanced CT scan.

Authors:  Michael Gayhart; Hiroshi Arisawa
Journal:  Comput Math Methods Med       Date:  2013-03-31       Impact factor: 2.238

10.  Feasibility of aortic valve assessment with low dose prospectively triggered adaptive systolic (PTAS) cardiac computed tomography angiography.

Authors:  Ashley M Lee; Jonathan Beaudoin; Wai-Ee Thai; Bryan Wai; Gladwin C Hui; Manavjot S Sidhu; Leif-Christopher Engel; Suhny Abbara; Udo Hoffmann; Brian B Ghoshhajra
Journal:  BMC Res Notes       Date:  2013-04-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.