Literature DB >> 17015107

Anterior odontoid fixation using a 4.5-mm Herbert screw: The first report of 20 consecutive cases with odontoid fracture.

Sun-Ho Lee1, Joo-Kyung Sung.   

Abstract

BACKGROUND: Anterior screw fixation provides the best anatomical and functional results for odontoid process fracture (type II and "shallow" type III) with intact transverse ligament. The purpose of this study is to evaluate the clinical results of the 4.5-mm-diameter cannulated Herbert screw in the anterior odontoid fixation.
METHODS: From May 2003 to November 2005, 20 consecutive cases of types II and III odontoid process fractures were treated with anterior screw fixation using a 4.5-mm Herbert screw. The Herbert screw has double threads, with different pitches on the distal and proximal ends. It has no head, so it can be inserted through articular cartilage and buried below bone surface.
RESULTS: There were 16 male and 4 female patients whose ages ranged from 15 to 76 years (mean, 43.7 years). The fracture type was type II-A in 4 patients, II-N in 9 patients, II-P in 5 patients, and III in 2 patients. The range of follow-up was 3 to 36 months (mean, 18.6 months). There were an overall bone fusion rate in 17 cases (85%), fibrous union in 1 (5%), and nonunion in 2 (10%). Overall, complication unrelated to hardware occurred in the one (postoperative dysphagia) without complication-related hardware failure.
CONCLUSIONS: The Herbert screw is very useful in anterior fixation for types II and III odontoid process fractures. This series showed successful clinical results comparable with that of the 3.5-mm cannulated cancellous screw and distinct advantages over conventional screws in the aspect of biomechanical properties and less invasiveness.

Entities:  

Mesh:

Year:  2006        PMID: 17015107     DOI: 10.1016/j.surneu.2006.04.018

Source DB:  PubMed          Journal:  Surg Neurol        ISSN: 0090-3019


  14 in total

1.  One-screw fixation provides similar stability to that of two-screw fixation for type II dens fractures.

Authors:  Gang Feng; Robert Wendlandt; Sebastian Spuck; Arndt P Schulz
Journal:  Clin Orthop Relat Res       Date:  2012-05-15       Impact factor: 4.176

2.  Is All Anterior Oblique Fracture Orientation Really a Contraindication to Anterior Screw Fixation of Type II and Rostral Shallow Type III Odontoid Fractures?

Authors:  Dae-Chul Cho; Joo-Kyung Sung
Journal:  J Korean Neurosurg Soc       Date:  2011-06-30

Review 3.  The impact of odontoid screw fixation techniques on screw-related complications and fusion rates: a systematic review and meta-analysis.

Authors:  Ivan Lvov; Andrey Grin; Aleksandr Talypov; Ivan Godkov; Anton Kordonskiy; Ulugbek Khushnazarov; Vladimir Smirnov; Vladimir Krylov
Journal:  Eur Spine J       Date:  2020-06-15       Impact factor: 3.134

4.  Efficacy of anterior odontoid screw fixation in the elderly patient: a CT-based biometrical analysis of odontoid fractures.

Authors:  Michael Mayer; Juliane Zenner; Alexander Auffarth; Jörg Atzwanger; Franz Romeder; Wolfgang Hitzl; Stefan Lederer; Herbert Resch; Heiko Koller
Journal:  Eur Spine J       Date:  2011-05-24       Impact factor: 3.134

5.  A meta-analysis of the fusion rate from surgical treatment for odontoid factures: anterior odontoid screw versus posterior C1-C2 arthrodesis.

Authors:  Ye Shen; Jinhao Miao; Chao Li; Lei Fang; Samantha Cao; Ming Zhang; Jianhua Yan; Yong Kuang
Journal:  Eur Spine J       Date:  2015-03-25       Impact factor: 3.134

6.  Clinical outcomes of halo-vest immobilization and surgical fusion of odontoid fractures.

Authors:  Seung Kook Kim; Jun Jae Shin; Tae Hong Kim; Hyung Shik Shin; Yong Soon Hwang; Sang Keun Park
Journal:  J Korean Neurosurg Soc       Date:  2011-07-31

7.  Computerized Tomography-Based Morphometric Analysis of Odontoid in 100 Egyptian Patients.

Authors:  Nirmal D Patil; Mohammad Essam; Raafat Kamal Ragab; Hesham Elsaghir
Journal:  Int J Spine Surg       Date:  2020-02-29

8.  CT based evaluation of odontoid morphology in the Indian population.

Authors:  Arvind G Kulkarni; Siddharth M Shah; Ruchira A Marwah; Prasad B Hanagandi; Inder R Talwar
Journal:  Indian J Orthop       Date:  2013-05       Impact factor: 1.251

9.  Pooled analysis of non-union, re-operation, infection, and approach related complications after anterior odontoid screw fixation.

Authors:  Nai-Feng Tian; Xu-Qi Hu; Li-Jun Wu; Xin-Lei Wu; Yao-Sen Wu; Xiao-Lei Zhang; Xiang-Yang Wang; Yong-Long Chi; Fang-Min Mao
Journal:  PLoS One       Date:  2014-07-24       Impact factor: 3.240

10.  Biomechanical Comparison of Inter-fragmentary Compression Pressures: Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation.

Authors:  Jin-Woo Park; Kyoung-Tae Kim; Joo-Kyung Sung; Seong-Hyun Park; Ki-Woong Seong; Dae-Chul Cho
Journal:  J Korean Neurosurg Soc       Date:  2017-08-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.