Diurnal variation of intraocular pressure in suspected normal-tension glaucoma.

Kou Hasegawa1, Kyoko Ishida1, Akira Sawada1, Kazuhide Kawase1, Tetsuya Yamamoto1.   

Abstract

PURPOSE: To assess diurnal variations of intraocular pressure (IOP) in suspected normal-tension glaucoma (NTG) patients with subsequent long-term observation to detect changes that may lead to a new diagnosis.
METHODS: Diurnal variation of IOP was measured in a sitting position at 2-h intervals for 24 h in a total of 569 subjects with suspected NTG.
RESULTS: Thirty of the 569 subjects (5.3%) showed IOP values exceeding 20 mmHg during the 24-h monitoring and were diagnosed as having primary open-angle glaucoma (POAG). In subjects in whom NTG was definitely diagnosed based on the results of the 24-h monitoring, the average maximum, minimum, and mean IOP was 16.1, 11.7, and 13.9 mmHg, respectively, and the mean diurnal variation in IOP was 4.4 mmHg. The peak time was observed outside clinic hours (1800-0800) in 41.4% of patients, and the trough time was observed during clinic hours (1000-1600) in 15.9%. In 2.9% of NTG subjects, the diagnosis was eventually changed to POAG during follow-up.
CONCLUSION: Assessment of diurnal variations of IOP in suspected NTG patients is useful for the differential diagnosis of POAG from NTG and for establishment of a baseline, which may affect the management plan. Copyright Japanese Ophthalmological Society 2006.

Entities:  

Mesh:

Year:  2006        PMID: 17013698     DOI: 10.1007/s10384-006-0343-z

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  27 in total

1.  Elevation of human intraocular pressure at night under moderate illumination.

Authors:  J H Liu; D F Kripke; R E Hoffman; M D Twa; R T Loving; K M Rex; B L Lee; S L Mansberger; R N Weinreb
Journal:  Invest Ophthalmol Vis Sci       Date:  1999-09       Impact factor: 4.799

2.  Diurnal variation of intraocular pressure in primary open-angle glaucoma.

Authors:  Y Kitazawa; T Horie
Journal:  Am J Ophthalmol       Date:  1975-04       Impact factor: 5.258

3.  [Intraocular pressure in normal human eyes].

Authors:  W LEYDHECKER; K AKIYAMA; H G NEUMANN
Journal:  Klin Monbl Augenheilkd Augenarztl Fortbild       Date:  1958

4.  Monthly measurements of intraocular pressure in normal, ocular hypertensive, and glaucoma male subjects of same age group.

Authors:  I A Qureshi; X R Xi; I H Khan; X D Wu; Y B Huang
Journal:  Changgeng Yi Xue Za Zhi       Date:  1997-09

5.  A circadian rhythm of aqueous flow underlies the circadian rhythm of IOP in NZW rabbits.

Authors:  S D Smith; D S Gregory
Journal:  Invest Ophthalmol Vis Sci       Date:  1989-04       Impact factor: 4.799

6.  Racial variations in the prevalence of primary open-angle glaucoma. The Baltimore Eye Survey.

Authors:  J M Tielsch; A Sommer; J Katz; R M Royall; H A Quigley; J Javitt
Journal:  JAMA       Date:  1991-07-17       Impact factor: 56.272

7.  Factors contributing to the progression of visual field damage in eyes with normal-tension glaucoma.

Authors:  M Araie; M Sekine; Y Suzuki; N Koseki
Journal:  Ophthalmology       Date:  1994-08       Impact factor: 12.079

8.  Comparison of glaucomatous progression between untreated patients with normal-tension glaucoma and patients with therapeutically reduced intraocular pressures. Collaborative Normal-Tension Glaucoma Study Group.

Authors: 
Journal:  Am J Ophthalmol       Date:  1998-10       Impact factor: 5.258

9.  The effectiveness of intraocular pressure reduction in the treatment of normal-tension glaucoma. Collaborative Normal-Tension Glaucoma Study Group.

Authors: 
Journal:  Am J Ophthalmol       Date:  1998-10       Impact factor: 5.258

10.  Twenty-four-hour intraocular pressure pattern associated with early glaucomatous changes.

Authors:  John H K Liu; Xiaoyan Zhang; Daniel F Kripke; Robert N Weinreb
Journal:  Invest Ophthalmol Vis Sci       Date:  2003-04       Impact factor: 4.799

View more
  12 in total

1.  [Correction factors for central corneal thickness in Goldmann applanation tonometry].

Authors:  A Kutschan; B Schroeder; A Hager; H Dave; K Wegscheider; W Wiegand
Journal:  Ophthalmologe       Date:  2010-01       Impact factor: 1.059

2.  Circadian intraocular pressure profiles in chronic open angle glaucomas.

Authors:  Jost B Jonas; Wido M Budde; Andrea Stroux; Isabel M Oberacher-Velten; Anselm G Juenemann
Journal:  J Ophthalmic Vis Res       Date:  2010-04

3.  Short-Term Reproducibility of Twenty-Four-Hour Intraocular Pressure Curves in Untreated Patients with Primary Open-Angle Glaucoma and Ocular Hypertension.

Authors:  Shuo Xu; Qin Jiao; Yu Cheng; Jie Sun; Qiong Lu; Yisheng Zhong
Journal:  PLoS One       Date:  2015-10-14       Impact factor: 3.240

4.  Diurnal intraocular pressure with bimatoprost/timolol fixed combination versus latanoprost/timolol fixed combination in healthy subjects.

Authors:  Seong Hee Shim; Joon Mo Kim; Chul Young Choi; Chan Yun Kim
Journal:  Korean J Ophthalmol       Date:  2014-01-21

5.  The Effect of Diurnal Fluctuation in Intraocular Pressure on the Evaluation of Risk Factors of Progression in Normal Tension Glaucoma.

Authors:  Seung Hoon Kim; Eun Jung Lee; Jong Chul Han; Sae Woon Sohn; Taekkwan Rhee; Changwon Kee
Journal:  PLoS One       Date:  2016-10-24       Impact factor: 3.240

6.  Intraocular pressure response affected by changing of sitting and supine positions.

Authors:  Eliška Najmanová; František Pluháček; Markéta Haklová
Journal:  Acta Ophthalmol       Date:  2019-10-10       Impact factor: 3.761

7.  Factors Influencing the Placebo Effect in Patients with Primary Open-Angle Glaucoma or Ocular Hypertension: An Analysis of Two Randomized Clinical Trials.

Authors:  Taichi Kawamura; Izumi Sato; Koji Kawakami
Journal:  PLoS One       Date:  2016-06-02       Impact factor: 3.240

8.  Diurnal Intraocular Pressure Fluctuations with Self-tonometry in Glaucoma Patients and Suspects: A Clinical Trial.

Authors:  Jessie Huang; Paula Katalinic; Michael Kalloniatis; Michael P Hennessy; Barbara Zangerl
Journal:  Optom Vis Sci       Date:  2018-02       Impact factor: 1.973

Review 9.  Intraocular Pressure Fluctuation: Is It Important?

Authors:  Ji Hyun Kim; Joseph Caprioli
Journal:  J Ophthalmic Vis Res       Date:  2018 Apr-Jun

Review 10.  Diurnal and 24-h Intraocular Pressures in Glaucoma: Monitoring Strategies and Impact on Prognosis and Treatment.

Authors:  Anastasios G Konstas; Malik Y Kahook; Makoto Araie; Andreas Katsanos; Luciano Quaranta; Luca Rossetti; Gábor Holló; Efstathios T Detorakis; Francesco Oddone; Dimitrios G Mikropoulos; Gordon N Dutton
Journal:  Adv Ther       Date:  2018-10-20       Impact factor: 3.845

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.