Literature DB >> 17013657

Technical strategies and anatomic considerations for parapedicular access to thoracic and lumbar vertebral bodies.

Douglas P Beall1, John J Braswell, Hal D Martin, Annette M Stapp, Timothy A Puckett, M T Stechison.   

Abstract

OBJECTIVES: To investigate and illustrate a variation on the traditional percutaneous access to the vertebral body via a parapedicular approach.
DESIGN: An effective parapedicular access technique that could safely and reliably guide the needle tip into the center of the vertebral body was developed from cadaver dissection observations for the purpose of clinical use. PATIENTS: A total of 102 vertebral compression fractures from T-4 to L-5 were treated via the parapedicular access at our institution between July 2005 and March 2006. There were 72 patients between the ages of 17 and 96 years (mean age: 68.2 years) who underwent treatment.
RESULTS: The cadaver dissection revealed a relatively avascular and aneural portion of the vertebral body along the superior margin of the vertebral body-pedicle junction. A total 102 vertebral fractures were treated using the parapedicular access technique without any recognized clinical complications from the needle access or the instrumentation.
CONCLUSIONS: The thoracic and lumbar vertebral bodies may be safely, reliably, and reproducibly accessed using a percutaneous parapedicular access technique. The technique presented represents a relatively avascular and aneural approach to vertebral body.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17013657     DOI: 10.1007/s00256-006-0192-3

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  10 in total

1.  An evaluation of image-guided technologies in the placement of anterior thoracic vertebral body screws in spinal trauma: a cadaver study.

Authors:  Alexander R Vaccaro; Philip S Yuan; Harvey E Smith; Jonathon Hott; Rick Sasso; Stephen Papadopoulos
Journal:  J Spinal Cord Med       Date:  2005       Impact factor: 1.985

2.  Incidence of clinically diagnosed vertebral fractures: a population-based study in Rochester, Minnesota, 1985-1989.

Authors:  C Cooper; E J Atkinson; W M O'Fallon; L J Melton
Journal:  J Bone Miner Res       Date:  1992-02       Impact factor: 6.741

3.  Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment.

Authors:  A R Vaccaro; S J Rizzolo; R A Balderston; T J Allardyce; S R Garfin; C Dolinskas; H S An
Journal:  J Bone Joint Surg Am       Date:  1995-08       Impact factor: 5.284

4.  Percutaneous vertebroplasty with polymethylmethacrylate. Technique, indications, and results.

Authors:  H Deramond; C Depriester; P Galibert; D Le Gars
Journal:  Radiol Clin North Am       Date:  1998-05       Impact factor: 2.303

5.  [Percutaneous vertebral surgery. Technics and indications].

Authors:  J Chiras; C Depriester; A Weill; M T Sola-Martinez; H Deramond
Journal:  J Neuroradiol       Date:  1997-06       Impact factor: 3.447

6.  Extrapedicular approach of percutaneous vertebroplasty in the treatment of upper and mid-thoracic vertebral compression fracture.

Authors:  K R Han; C Kim; J S Eun; Y S Chung
Journal:  Acta Radiol       Date:  2005-05       Impact factor: 1.990

7.  Percutaneous vertebroplasty for pain relief and spinal stabilization.

Authors:  J D Barr; M S Barr; T J Lemley; R M McCann
Journal:  Spine (Phila Pa 1976)       Date:  2000-04-15       Impact factor: 3.468

8.  Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae.

Authors:  A R Vaccaro; S J Rizzolo; T J Allardyce; M Ramsey; J Salvo; R A Balderston; J M Cotler
Journal:  J Bone Joint Surg Am       Date:  1995-08       Impact factor: 5.284

9.  Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up.

Authors:  A Cotten; F Dewatre; B Cortet; R Assaker; D Leblond; B Duquesnoy; P Chastanet; J Clarisse
Journal:  Radiology       Date:  1996-08       Impact factor: 11.105

10.  [Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty].

Authors:  P Galibert; H Deramond; P Rosat; D Le Gars
Journal:  Neurochirurgie       Date:  1987       Impact factor: 1.553

  10 in total
  5 in total

Review 1.  Vertebroplasty.

Authors:  Bryan Jay; Sun Ho Ahn
Journal:  Semin Intervent Radiol       Date:  2013-09       Impact factor: 1.513

2.  Parapedicular vertebral augmentation with polymethylmetacrylate for pedicle screw loosening.

Authors:  Olivier Clerk-Lamalice; Zubin Irani; Marion Growney; Douglas P Beall; Joshua A Hirsch
Journal:  BMJ Case Rep       Date:  2018-01-24

Review 3.  Percutaneous treatment of insufficiency fractures : principles, technique and review of literature.

Authors:  Douglas P Beall; Abhijit Datir; Sharon L D'Souza; Logan S D'Souza; Divya Gunda; John Morelli; Michael Brandon Johnson; Nima Nabavizadeh
Journal:  Skeletal Radiol       Date:  2010-02       Impact factor: 2.199

Review 4.  Vertebral Compression Fractures: Evaluation and Management.

Authors:  Sreekumar Madassery
Journal:  Semin Intervent Radiol       Date:  2020-05-14       Impact factor: 1.513

5.  Long-Segmental Posterior Fusion Combined With Vertebroplasty and Wiring: Alternative Surgical Technique for Kummell's Disease With Neurologic Deficits-A Retrospective Case Series.

Authors:  Hyung-Youl Park; Ki-Won Kim; Ji-Hyun Ryu; S Tim Yoon; In-Hwa Baek; Tae-Yang Jang; Jun-Seok Lee
Journal:  Geriatr Orthop Surg Rehabil       Date:  2021-06-28
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.