Literature DB >> 17012308

Comparison of stroke volume (SV) and stroke volume respiratory variation (SVV) measured by the axillary artery pulse-contour method and by aortic Doppler echocardiography in patients undergoing aortic surgery.

V De Castro1, J-P Goarin, L Lhotel, N Mabrouk, A Perel, P Coriat.   

Abstract

BACKGROUND: The goal of the study was to compare stroke volume (SV) and respiratory stroke volume variation (SVV) measured by pulse-contour analysis and aortic Doppler.
METHODS: These were measured by pulse-contour analysis and thermodilution (PiCCO) and by aortic pulsed wave Doppler with transoesophageal echocardiography in patients undergoing abdominal aortic surgery. Simultaneous measurements were done at different times of surgery. All data were recorded on PiCCOwin software and videotape and analysed off-line by a blinded investigator.
RESULTS: A total of 114 measurements were achieved in 20 patients. There was a good correlation and small bias between the PiCCO and the echo-Doppler values of the mean SV [r=0.885; bias=0.2 (8) ml], and between the minimum [r=0.842; bias=1 (9) ml] and maximum SV [r=0.840; bias=2 (10) ml] values.
CONCLUSIONS: There is a fair correlation between pulse-contour analysis and aortic Doppler for beat-by-beat measurement of SV but not for calculation of SV respiratory ventilation.

Entities:  

Mesh:

Year:  2006        PMID: 17012308     DOI: 10.1093/bja/ael236

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  6 in total

1.  Ability of pulse power, esophageal Doppler, and arterial pulse pressure to estimate rapid changes in stroke volume in humans.

Authors:  José Marquez; Kenneth McCurry; Donald A Severyn; Michael R Pinsky
Journal:  Crit Care Med       Date:  2008-11       Impact factor: 7.598

Review 2.  The role of transesophageal echocardiography in the intraoperative period.

Authors:  Veronica Gouveia; Paulo Marcelino; Daniel A Reuter
Journal:  Curr Cardiol Rev       Date:  2011-08

3.  Basic concepts of fluid responsiveness.

Authors:  T G V Cherpanath; B F Geerts; W K Lagrand; M J Schultz; A B J Groeneveld
Journal:  Neth Heart J       Date:  2013-12       Impact factor: 2.380

4.  Pilot Study: Estimation of Stroke Volume and Cardiac Output from Pulse Wave Velocity.

Authors:  Yurie Obata; Maki Mizogami; Daniel Nyhan; Dan E Berkowitz; Jochen Steppan; Viachaslau Barodka
Journal:  PLoS One       Date:  2017-01-06       Impact factor: 3.240

5.  Comparison between radial artery tonometry pulse analyzer and pulsed-Doppler echocardiography derived hemodynamic parameters in cardiac surgery patients: a pilot study.

Authors:  Nima Hatam; Ali Aljalloud; Rashad Zayat; Andreas Goetzenich; Ju-Yeon Lee; HeeJung Kang; So-Hyun Jansen-Park; Thomas Schmitz-Rode; Giulia Musetti; Heike Schnoering; Rüdiger Autschbach
Journal:  PeerJ       Date:  2017-12-06       Impact factor: 2.984

Review 6.  Goal-directed therapy in intraoperative fluid and hemodynamic management.

Authors:  Maria Cristina Gutierrez; Peter G Moore; Hong Liu
Journal:  J Biomed Res       Date:  2013-03-10
  6 in total