Literature DB >> 17010869

Bacterial contamination in the anterior chamber after povidone-iodine application and the effect of the lens implantation device.

Mária Bausz1, Eszter Fodor, Miklós D Resch, Katalin Kristóf.   

Abstract

PURPOSE: To assess the incidence of anterior chamber bacterial contamination during cataract surgery, and compare results of injector implantation and forceps implantation of foldable intraocular lenses (IOLs).
SETTING: Department of Ophthalmology and Institute of Medical Microbiology, Semmelweis University, Budapest, Hungary.
METHODS: This prospective randomized controlled clinical study comprised 97 eyes of 96 patients. Antibiotic eyedrops were not used; however, povidone-iodine 10% solution was used to prepare the eyebrow and eyelids and povidone-iodine 5% to disinfect the ocular surface. A Steri-Drape (3M) was used to surround the eye. Aqueous fluid samples were aspirated from the anterior chamber at the beginning and the end of surgery. The samples were cultured for 14 days under aerobic and anaerobic conditions simultaneously. Cataract surgery was performed using a sutureless, superotemporal, clear corneal phacoemulsification technique. The IOL was implanted with an injector (n = 47) or a forceps (n = 50), with the instrument randomly selected. The frequency of positive bacterial cultures with each implantation method was compared using the Fisher exact test.
RESULTS: Bacteria were found in the conjunctival samples in 21 eyes (21.65%) before povidone-iodine application and in 4 eyes (4.12%) after disinfection. The anterior chamber sample before surgery was culture positive for Staphylococcus epidermidis in 2 eyes and for Micrococcus luteus in 1 eye. After surgery, the culture was positive for S epidermidis in 1 eye (2.15%) in the injector group and 1 eye (2.00%) in the forceps group (P = .74). Neither sample came from an eye that had a positive culture preoperatively. There were no intraoperative complications.
CONCLUSIONS: In uneventful clear corneal phacoemulsification, meticulous technique can prevent antibiotic use during surgery. No difference in anterior chamber bacterial contamination was found between IOL implantation using an injector or a forceps.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17010869     DOI: 10.1016/j.jcrs.2006.05.019

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  13 in total

1.  Evaluation of bacterial contamination rate of the anterior chamber during phacoemulsification surgery using an automated microbial detection system.

Authors:  Ibrahim Kocak; Funda Kocak; Bahri Teker; Ali Aydin; Faruk Kaya; Hakan Baybora
Journal:  Int J Ophthalmol       Date:  2014-08-18       Impact factor: 1.779

Review 2.  Bacterial endophthalmitis in the age of outpatient intravitreal therapies and cataract surgeries: host-microbe interactions in intraocular infection.

Authors:  Ama Sadaka; Marlene L Durand; Michael S Gilmore
Journal:  Prog Retin Eye Res       Date:  2012-04-11       Impact factor: 21.198

3.  A Case of Delayed-Onset Propionibacterium acnes Endophthalmitis after Cataract Surgery with Implantation of a Preloaded Intraocular Lens.

Authors:  Yuki Hayashi; Hiroshi Eguchi; Tatsuro Miyamoto; Masayuki Inoue; Yoshinori Mitamura
Journal:  Case Rep Ophthalmol       Date:  2012-09-11

4.  Comparison of different techniques of cataract surgery in bacterial contamination of the anterior chamber in diabetic and non-diabetic population.

Authors:  M Ashok Kumar; Sheen S Kurien; Stephen Selvaraj; Uma Devi; S Selvasundari
Journal:  Indian J Ophthalmol       Date:  2012 Jan-Feb       Impact factor: 1.848

Review 5.  Biofilms in infections of the eye.

Authors:  Paulo J M Bispo; Wolfgang Haas; Michael S Gilmore
Journal:  Pathogens       Date:  2015-03-23

6.  Comparison of Biofilm Formation Capacities of Two Clinical Isolates of Staphylococcus Epidermidis with and without icaA and icaD Genes on Intraocular Lenses.

Authors:  Sertaç Argun Kıvanç; Merih Kıvanç; Volkan Kılıç; Gülay Güllülü; Ahmet Tuncer Özmen
Journal:  Turk J Ophthalmol       Date:  2017-04-01

7.  Efficacy of intraoperative vancomycin in irrigating solutions on aqueous contamination during phacoemulsification.

Authors:  Renuka Srinivasan; Arvind Gupta; Subashini Kaliaperumal; Ramesh K Babu; Senthil Kumar Thimmarayan; Harish Narasimha Belgode
Journal:  Indian J Ophthalmol       Date:  2008 Sep-Oct       Impact factor: 1.848

8.  Ophthalmic viscosurgical device backflow into cartridge during intraocular lens insertion using injectors.

Authors:  Kazuki Matsuura; Yoshitsugu Inoue
Journal:  Clin Ophthalmol       Date:  2014-01-31

9.  Anterior chamber bacterial contamination in cataract surgery.

Authors:  Jorge E Valdez-García; Alejandro Climent; Eduardo Chávez-Mondragón; Juan F Lozano-Ramírez
Journal:  BMC Ophthalmol       Date:  2014-04-30       Impact factor: 2.209

10.  Evaluation of the vitreous microbial contamination rate in office-based three-port microincision vitrectomy surgery using Retrector technology.

Authors:  Flavio A Rezende; Cynthia X Qian; Przemyslaw Sapieha
Journal:  BMC Ophthalmol       Date:  2014-05-01       Impact factor: 2.209

View more