Literature DB >> 17010612

Evaluation of instrumented shoes for ambulatory assessment of ground reaction forces.

Christian Liedtke1, Steven A W Fokkenrood, Jasper T Menger, Herman van der Kooij, Peter H Veltink.   

Abstract

Currently, force plates or pressure sensitive insoles are the standard tools to measure ground reaction forces and centre of pressure data during human gait. Force plates, however, impose constraints on foot placement, and the available pressure sensitive insoles measure only one component of force. In this study, shoes instrumented with two force transducers measuring forces and moments in three dimensions were evaluated. Technical performance was assessed by comparing force measurement and centre of pressure reconstructions of the instrumented shoes against a force plate. The effect of the instrumented shoes on gait was investigated using an optical tracking system and a force plate. Instrumented shoes were compared against normal shoes and weighted shoes. The ground reaction force measured with force plate and instrumented shoes differed by 2.2+/-0.1% in magnitude and by 3.4+/-1.3 degrees in direction. The horizontal components differed by 9.9+/-3.8% in magnitude and 26.9+/-10.0 degrees in direction. Centre of pressure location differed by 13.7+/-2.4mm between measurement systems. A MANOVA repeated measures analysis on data of seven subjects, revealed significant differences in gait pattern between shoe types (p</=0.05). A subsequent univariate analysis showed significant differences only in maximum ground reaction force but these could not be attributed to specific shoe types by pair-wise comparison. This study indicates that shoes instrumented with force transducers can be a valuable alternative to current measurement systems if accurate sensing of position and orientation of the force transducers is improved. They are applicable in ambulatory settings and suitable for inverse dynamics analysis.

Entities:  

Mesh:

Year:  2006        PMID: 17010612     DOI: 10.1016/j.gaitpost.2006.07.017

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  18 in total

1.  Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior.

Authors:  Katrien Van Nimmen; Geert Lombaert; Guido De Roeck; Peter Van den Broeck
Journal:  J Vis Exp       Date:  2016-04-13       Impact factor: 1.355

2.  Influence of the instrumented force shoe on gait pattern in patients with osteoarthritis of the knee.

Authors:  Josien van den Noort; Martin van der Esch; Martijn P Steultjens; Joost Dekker; Martin Schepers; Peter H Veltink; Jaap Harlaar
Journal:  Med Biol Eng Comput       Date:  2011-08-25       Impact factor: 2.602

3.  A wearable ground reaction force sensor system and its application to the measurement of extrinsic gait variability.

Authors:  Tao Liu; Yoshio Inoue; Kyoko Shibata
Journal:  Sensors (Basel)       Date:  2010-11-16       Impact factor: 3.576

Review 4.  Gait analysis using wearable sensors.

Authors:  Weijun Tao; Tao Liu; Rencheng Zheng; Hutian Feng
Journal:  Sensors (Basel)       Date:  2012-02-16       Impact factor: 3.576

5.  Estimation of ground reaction forces and ankle moment with multiple, low-cost sensors.

Authors:  Daniel A Jacobs; Daniel P Ferris
Journal:  J Neuroeng Rehabil       Date:  2015-10-14       Impact factor: 4.262

6.  Estimation of Ground Reaction Forces and Moments During Gait Using Only Inertial Motion Capture.

Authors:  Angelos Karatsidis; Giovanni Bellusci; H Martin Schepers; Mark de Zee; Michael S Andersen; Peter H Veltink
Journal:  Sensors (Basel)       Date:  2016-12-31       Impact factor: 3.576

7.  Pre-operative ambulatory measurement of asymmetric lower limb loading during walking in total hip arthroplasty patients.

Authors:  Alicia Martínez-Ramírez; Dirk Weenk; Pablo Lecumberri; Nico Verdonschot; Dean Pakvis; Peter H Veltink
Journal:  J Neuroeng Rehabil       Date:  2013-04-20       Impact factor: 4.262

8.  Assessment of asymmetric leg loading before and after total hip arthroplasty using instrumented shoes.

Authors:  Alicia Martínez-Ramírez; Dirk Weenk; Pablo Lecumberri; Nico Verdonschot; Dean Pakvis; Peter H Veltink
Journal:  J Neuroeng Rehabil       Date:  2014-02-28       Impact factor: 4.262

9.  Evaluation of two approaches for aligning data obtained from a motion capture system and an in-shoe pressure measurement system.

Authors:  Sunwook Kim; Maury A Nussbaum
Journal:  Sensors (Basel)       Date:  2014-09-12       Impact factor: 3.576

10.  Three-Axis Ground Reaction Force Distribution during Straight Walking.

Authors:  Masataka Hori; Akihito Nakai; Isao Shimoyama
Journal:  Sensors (Basel)       Date:  2017-10-24       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.