Literature DB >> 17009400

Postprandial transduodenal bolus transport is regulated by complex peristaltic sequence.

Huan Nam Nguyen1, Ron Winograd, Gerson Ricardo Souza Domingues, Frank Lammert.   

Abstract

AIM: To study the relationship between the patterns of postprandial peristalsis and transduodenal bolus transport in healthy subjects.
METHODS: Synchronous recording of chyme transport and peristaltic activity was performed during the fasting state and after administration of a test meal using a special catheter device with cascade configuration of impedance electrodes and solid-state pressure transducers. The catheter was placed into the duodenum, where the first channel was located in the first part of the duodenum and the last channel at the duodenojejunal junction. After identification of previously defined chyme transport patterns the associated peristaltic patterns were analyzed.
RESULTS: The interdigestive phase 3 complex was reliably recorded with both techniques. Of 497 analyzed impedance bolus transport events, 110 (22%) were short-spanned propulsive, 307 (62%) long-spanned propulsive, 70 (14%) complex propulsive, and 10 (2%) retrograde transport. Short-spanned chyme transports were predominantly associated with stationary or propagated contractions propagated over short distance. Long-spanned and complex chyme transports were predominantly associated with propulsive peristaltic patterns, which were frequently complex and comprised multiple contractions. Propagated double wave contraction, propagated contraction with a clustered contraction, and propagated cluster of contractions have been identified to be an integralted part of a peristaltic sequence in human duodenum.
CONCLUSION: Combined impedancometry and manometry improves the analysis of the peristaltic patterns that are associated with postprandial transduodenal chyme transport. Postprandial transduodenal bolus transport is regulated by propulsive peristaltic patterns, which are frequently complex but well organized. This finding should be taken into consideration in the analysis of intestinal motility studies.

Entities:  

Mesh:

Year:  2006        PMID: 17009400      PMCID: PMC4124409          DOI: 10.3748/wjg.v12.i37.6008

Source DB:  PubMed          Journal:  World J Gastroenterol        ISSN: 1007-9327            Impact factor:   5.742


  35 in total

Review 1.  Of slow waves and spike patches.

Authors:  W J Lammers; J R Slack
Journal:  News Physiol Sci       Date:  2001-06

2.  Study of intestinal flow by combined videofluoroscopy, manometry, and multiple intraluminal impedance.

Authors:  Hala Imam; Claudia Sanmiguel; Brett Larive; Yasser Bhat; Edy Soffer
Journal:  Am J Physiol Gastrointest Liver Physiol       Date:  2003-09-25       Impact factor: 4.052

3.  Similarities and differences in the propagation of slow waves and peristaltic waves.

Authors:  Wim J E P Lammers; Betty Stephen; John R Slack
Journal:  Am J Physiol Gastrointest Liver Physiol       Date:  2002-09       Impact factor: 4.052

4.  Impedance characteristics of normal oesophageal motor function.

Authors:  Huan N Nguyen; Gerson R Domingues; Ron Winograd; Patrick Koppitz; Frank Lammert; Jiri Silny; Siegfried Matern
Journal:  Eur J Gastroenterol Hepatol       Date:  2003-07       Impact factor: 2.566

5.  Longitudinal and circumferential spike patches in the canine small intestine in vivo.

Authors:  Wim J E P Lammers; Luc Ver Donck; Jan A J Schuurkes; Betty Stephen
Journal:  Am J Physiol Gastrointest Liver Physiol       Date:  2003-07-03       Impact factor: 4.052

6.  Interdigestive transpyloric fluid transport assessed by intraluminal impedance recording.

Authors:  G Savoye; C Savoye-Collet; J Oors; A J P M Smout
Journal:  Am J Physiol Gastrointest Liver Physiol       Date:  2002-12-18       Impact factor: 4.052

7.  Relationship between bolus transit and LES-relaxation studied with concurrent impedance and manometry.

Authors:  H N Nguyen; G R Domingues; R Winograd; F Lammert; J Silny; S Matern
Journal:  Hepatogastroenterology       Date:  2006 Mar-Apr

8.  Acid, nonacid, and gas reflux in patients with gastroesophageal reflux disease during ambulatory 24-hour pH-impedance recordings.

Authors:  D Sifrim; R Holloway; J Silny; Z Xin; J Tack; A Lerut; J Janssens
Journal:  Gastroenterology       Date:  2001-06       Impact factor: 22.682

9.  Esophageal function testing using multichannel intraluminal impedance.

Authors:  R Srinivasan; M F Vela; P O Katz; R Tutuian; J A Castell; D O Castell
Journal:  Am J Physiol Gastrointest Liver Physiol       Date:  2001-03       Impact factor: 4.052

10.  Determinants of transpyloric fluid transport: a study using combined real-time ultrasound, manometry, and impedance recording.

Authors:  Céline Savoye-Collet; Guillaume Savoye; André Smout
Journal:  Am J Physiol Gastrointest Liver Physiol       Date:  2003-07-17       Impact factor: 4.052

View more
  1 in total

1.  Changes in morphology and function in small intestinal mucosa after Roux-en-Y surgery in a rat model.

Authors:  Pavlo L Kovalenko; Marc D Basson
Journal:  J Surg Res       Date:  2012-03-30       Impact factor: 2.192

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.