Literature DB >> 17009044

Immunization of Rhesus monkeys with a SialylTn-mAb17-1A conjugate vaccine co-formulated with QS-21 induces a temporary systemic cytokine release and NK cytotoxicity against tumor cells.

Ralf Kircheis1, Petra Siegl, Susanne Grunt, Nicole Halanek, Hans Loibner, Geert C Mudde, Andreas Nechansky.   

Abstract

Tumor-associated antigens resulting from aberrant glycosylation, such as the SialylTn carbohydrate antigen, are frequently over-expressed on cancer cells and provide potential targets for cancer vaccination. Immunization of Rhesus monkeys with SialylTn coupled to a highly immunogenic carrier molecule and formulated on aluminum hydroxide induced a strong immune response against the carrier protein but only a moderate IgM immune response against the SialylTn carbohydrate antigen. Co-formulation with QS-21 adjuvant dramatically enhanced the anti-SialylTn immune response and resulted in a SialylTn-specific IgG switch. The kinetics of the carbohydrate-specific IgG response correlated with a temporary release of cytokines such as IFNgamma, IL-2, IL-1beta, TNFalpha and GM-CSF which was measurable in the immune serum by xMAP Multiplex technology. Furthermore, tumor cell killing by activated natural killer cells was induced. These data demonstrate that immunization with a tumor-associated carbohydrate antigen in a highly immunogenic formulation results in a temporary release of type 1 cytokines which may be required for the induction of a specific IgG immune response against the carbohydrate antigen as well as for activation of effector cells against tumor cells.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17009044     DOI: 10.1007/s00262-006-0231-x

Source DB:  PubMed          Journal:  Cancer Immunol Immunother        ISSN: 0340-7004            Impact factor:   6.968


  2 in total

1.  Correlation of ADCC activity with cytokine release induced by the stably expressed, glyco-engineered humanized Lewis Y-specific monoclonal antibody MB314.

Authors:  Ralf Kircheis; Nicole Halanek; Iris Koller; Wolfgang Jost; Manfred Schuster; Gilbert Gorr; Klaus Hajszan; Andreas Nechansky
Journal:  MAbs       Date:  2012-07-01       Impact factor: 5.857

2.  Comparison of the Calibration Standards of Three Commercially Available Multiplex Kits for Human Cytokine Measurement to WHO Standards Reveals Striking Differences.

Authors:  Andreas Nechansky; Susanne Grunt; Ivan M Roitt; Ralf Kircheis
Journal:  Biomark Insights       Date:  2008-04-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.