Literature DB >> 17007526

Flow-through multianalyte chemiluminescent immunosensing system with designed substrate zone-resolved technique for sequential detection of tumor markers.

Zhifeng Fu1, Hong Liu, Huangxian Ju.   

Abstract

A novel flow-through immunosensing system for performing a multianalyte chemiluminescent determination in a single run was designed. A new analytical strategy of substrate zone-resolved technique was proposed. Using carcinoma antigen 125 (CA 125) and carcinoembryonic antigen (CEA) as model analytes, the capture antibodies for CA 125 and CEA were immobilized on an UltraBind aldehyde-activated membrane to act as an immunoreactor, to which the mixture of CA 125, CEA, and their corresponding tracers, horseradish peroxidase (HRP)-labeled anti-CA 125 and alkaline phosphatase (ALP)-labeled anti-CEA, was introduced for on-line incubation. The substrates for HRP and ALP were then delivered into the detection cell sequentially to perform substrate zone-resolved immunoassay by a sandwich format. Under optimal conditions, CA 125 and CEA could be assayed in the ranges of 5.0-100 units/mL and 1.0-120 ng/mL, respectively. The whole assay process including incubation, wash, detection, and regeneration could be completed in 35 min. The serum samples from the clinic were assayed with the proposed method, and the results were in acceptable agreement with the reference values. This method and the strategy of substrate zone-resolved technique could be further developed for high-throughput multianalyte immunoassay.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17007526     DOI: 10.1021/ac0610560

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Efficient label-free chemiluminescent immunosensor based on dual functional cupric oxide nanorods as peroxidase mimics.

Authors:  Juan Li; Yue Cao; Samuel S Hinman; Kristy S McKeating; Yiwen Guan; Xiaoya Hu; Quan Cheng; Zhanjun Yang
Journal:  Biosens Bioelectron       Date:  2017-09-09       Impact factor: 10.618

2.  Colorimetric immunoassay for detection of tumor markers.

Authors:  Yongmei Yin; Ya Cao; Yuanyuan Xu; Genxi Li
Journal:  Int J Mol Sci       Date:  2010-12-07       Impact factor: 5.923

3.  Chemiluminescent immunoassay technology: what does it change in autoantibody detection?

Authors:  Luigi Cinquanta; Desré Ethel Fontana; Nicola Bizzaro
Journal:  Auto Immun Highlights       Date:  2017-06-24

4.  Sensitive Bioanalysis Based on in-Situ Droplet Anodic Stripping Voltammetric Detection of CdS Quantum Dots Label after Enhanced Cathodic Preconcentration.

Authors:  Xiaoli Qin; Linchun Wang; Qingji Xie
Journal:  Sensors (Basel)       Date:  2016-08-23       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.