Literature DB >> 17006754

Evaluation of Goldmann applanation tonometry using a nonlinear finite element ocular model.

Ahmed Elsheikh1, Defu Wang, Aachal Kotecha, Michael Brown, David Garway-Heath.   

Abstract

Goldmann applanation tonometry (GAT) is the internationally accepted standard for intra-ocular pressure (IOP) measurement, which is important for the diagnosis of glaucoma. The technique does not consider the effect of the natural variation in the corneal thickness, curvature and material properties. As these parameters affect the structural resistance of the cornea, their variation is expected to lead to inaccuracies in IOP determination. Numerical Analysis based on the finite element method has been used to simulate the loading conditions experienced in GAT and hence assess the effect of variation in corneal parameters on GAT IOP measurements. The analysis is highly nonlinear and considers the hyper-elastic J-shaped stress-strain properties of corneal tissue observed in laboratory tests. The results reveal a clear association between both the corneal thickness and material properties, and the measured IOP. Corneal curvature has a considerably lower effect. Similar trends have been found from analysis of clinical data involving 532 patients referred to the Glaucoma Unit at Moorfields Hospital, and from earlier mathematical analyses. Nonlinear modelling is shown to trace the behaviour of the cornea under both IOP and tonometric pressure, and to be able to provide additional, and potentially useful, information on the distribution of stress, strain, contact pressure and gap closure.

Entities:  

Mesh:

Year:  2006        PMID: 17006754     DOI: 10.1007/s10439-006-9191-8

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  9 in total

1.  An evaluation of the effects of eyeball structure on ocular pulse amplitude in healthy subjects.

Authors:  Kotaro Ishii; Mikiro Mori; Tetsuro Oshika
Journal:  Int Ophthalmol       Date:  2012-07-20       Impact factor: 2.031

2.  MR elastography of the ex vivo bovine globe.

Authors:  Daniel V Litwiller; Sung J Lee; Arunark Kolipaka; Yogesh K Mariappan; Kevin J Glaser; Jose S Pulido; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2010-07       Impact factor: 4.813

Review 3.  The thick and thin of the central corneal thickness in glaucoma.

Authors:  Graham W Belovay; Ivan Goldberg
Journal:  Eye (Lond)       Date:  2018-02-15       Impact factor: 3.775

4.  The chinese american eye study: design and methods.

Authors:  Rohit Varma; Chunyi Hsu; Dandan Wang; Mina Torres; Stanley P Azen
Journal:  Ophthalmic Epidemiol       Date:  2013-09-18       Impact factor: 1.648

5.  Goldmann Tonometer Prism with an Optimized Error Correcting Applanation Surface.

Authors:  Sean McCafferty; Garrett Lim; William Duncan; Eniko Enikov; Jim Schwiegerling
Journal:  Transl Vis Sci Technol       Date:  2016-09-09       Impact factor: 3.283

6.  Comparison of Patient-Specific Computational Modeling Predictions and Clinical Outcomes of LASIK for Myopia.

Authors:  Ibrahim Seven; Ali Vahdati; Vinicius Silbiger De Stefano; Ronald R Krueger; William J Dupps
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-11-01       Impact factor: 4.799

7.  Biomechanical Simulation of Stress Concentration and Intraocular Pressure in Corneas Subjected to Myopic Refractive Surgical Procedures.

Authors:  Po-Jen Shih; I-Jong Wang; Wen-Feng Cai; Jia-Yush Yen
Journal:  Sci Rep       Date:  2017-10-24       Impact factor: 4.379

8.  A clinical method for estimating the modulus of elasticity of the human cornea in vivo.

Authors:  David C Pye
Journal:  PLoS One       Date:  2020-01-08       Impact factor: 3.240

9.  Ex vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness.

Authors:  Charles Whitford; Akram Joda; Steve Jones; Fangjun Bao; Paolo Rama; Ahmed Elsheikh
Journal:  Eye Vis (Lond)       Date:  2016-08-10
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.