Literature DB >> 17005732

Bacterial safety of flash-heated and unheated expressed breastmilk during storage.

K Israel-Ballard1, A Coutsoudis, C J Chantry, A W Sturm, F Karim, L Sibeko, B Abrams.   

Abstract

Heat-treated breastmilk is one infant-feeding option recommended by the WHO to reduce mother-to-child transmission of HIV in developing countries. Flash-heat, a simple pasteurization method that a mother could perform in her home, has been shown to inactivate cell-free HIV-1. Since heating may affect the naturally occurring antimicrobial properties found in breastmilk, storing heated breastmilk may present a safety issue in resource-poor settings due to lack of refrigeration and potential contamination. To address this, we investigated the ability of flash-heat to eliminate bacteria and to prevent growth over time compared with unheated breastmilk. We collected breastmilk samples from 38 HIV positive mothers in South Africa and aliquoted them to flash-heated and unheated controls. Samples were stored at room temperature for 0, 2, 6 and 8 h and then plated and incubated for 24 h at 37 degrees C in CO(2). We performed total colony counts and identified Escherichia coli, Staphylocuccus aureus and Group A and Group B streptococci. Unheated samples had a significantly higher number of samples positive for bacterial growth at each time point (p < 0.0001), as well as mean colony-forming units (CFU)/ml in those samples that were positive at each time point (p < 0.0001). In addition, unheated samples had a significantly higher rate of bacterial propagation over time than flash-heated samples when comparing log values of CFU/ml across 0-8 h (p < 0.005). No pathogenic growth was observed in the flash-heated samples, while the unheated samples showed growth of E. coli (n = 1) and S. aureus (n = 6). Our data suggest that storage of flash-heated breastmilk is safe at room temperature for up to 8 h.

Entities:  

Mesh:

Year:  2006        PMID: 17005732     DOI: 10.1093/tropej/fml043

Source DB:  PubMed          Journal:  J Trop Pediatr        ISSN: 0142-6338            Impact factor:   1.165


  13 in total

1.  Demonstrating the efficacy of the FoneAstra pasteurization monitor for human milk pasteurization in resource-limited settings.

Authors:  Mageshree Naicker; Anna Coutsoudis; Kiersten Israel-Ballard; Rohit Chaudhri; Noah Perin; Koleka Mlisana
Journal:  Breastfeed Med       Date:  2015-02-10       Impact factor: 1.817

2.  Effect of flash-heat treatment on antimicrobial activity of breastmilk.

Authors:  Caroline J Chantry; Jean Wiedeman; Gertrude Buehring; Janet M Peerson; Kweku Hayfron; Okumu K'Aluoch; Bo Lonnerdal; Kiersten Israel-Ballard; Anna Coutsoudis; Barbara Abrams
Journal:  Breastfeed Med       Date:  2010-11-23       Impact factor: 1.817

3.  Feasibility of using flash-heated breastmilk as an infant feeding option for HIV-exposed, uninfected infants after 6 months of age in urban Tanzania.

Authors:  Caroline J Chantry; Sera L Young; Waverly Rennie; Monica Ngonyani; Clara Mashio; Kiersten Israel-Ballard; Janet Peerson; Margaret Nyambo; Mecky Matee; Deborah Ash; Kathryn Dewey; Peggy Koniz-Booher
Journal:  J Acquir Immune Defic Syndr       Date:  2012-05-01       Impact factor: 3.731

4.  Heat treatment of expressed breast milk is a feasible option for feeding HIV-exposed, uninfected children after 6 months of age in rural Zimbabwe.

Authors:  Mduduzi N N Mbuya; Jean H Humphrey; Florence Majo; Bernard Chasekwa; Alison Jenkins; Kiersten Israel-Ballard; Monica Muti; Keriann H Paul; Rufaro C Madzima; Lawrence H Moulton; Rebecca J Stoltzfus
Journal:  J Nutr       Date:  2010-06-23       Impact factor: 4.798

5.  Addressing social barriers and closing the gender knowledge gap: exposure to road shows is associated with more knowledge and more positive beliefs, attitudes and social norms regarding exclusive breastfeeding in rural Zimbabwe.

Authors:  Alison L Jenkins; Naume V Tavengwa; Bernard Chasekwa; Kumbirai Chatora; Noah Taruberekera; Wellington Mushayi; Rufaro C Madzima; Mduduzi N N Mbuya
Journal:  Matern Child Nutr       Date:  2011-10-06       Impact factor: 3.092

6.  Vitamin content of breast milk from HIV-1-infected mothers before and after flash-heat treatment.

Authors:  Kiersten A Israel-Ballard; Barbara F Abrams; Anna Coutsoudis; Lindiwe N Sibeko; Lynn A Cheryk; Caroline J Chantry
Journal:  J Acquir Immune Defic Syndr       Date:  2008-08-01       Impact factor: 3.731

Review 7.  Current knowledge and future research on infant feeding in the context of HIV: basic, clinical, behavioral, and programmatic perspectives.

Authors:  Sera L Young; Mduduzi N N Mbuya; Caroline J Chantry; Eveline P Geubbels; Kiersten Israel-Ballard; Deborah Cohan; Stephen A Vosti; Michael C Latham
Journal:  Adv Nutr       Date:  2011-04-30       Impact factor: 8.701

8.  Impact of pasteurization on the antibacterial properties of human milk.

Authors:  Marjan Van Gysel; Veerle Cossey; Steffen Fieuws; Annette Schuermans
Journal:  Eur J Pediatr       Date:  2012-05-12       Impact factor: 3.183

9.  Barriers and promoters of home-based pasteurization of breastmilk among HIV-infected mothers in greater Dar es Salaam, Tanzania.

Authors:  Sera Young; Sebalda Leshabari; Chaele Arkfeld; Jennifer Singler; Emily Dantzer; Kiersten Israel-Ballard; Clara Mashio; Catherine Maternowska; Caroline Chantry
Journal:  Breastfeed Med       Date:  2012-11-06       Impact factor: 1.817

10.  Development of an AFASS assessment and screening tool towards the prevention of mother-to-child HIV transmission (PMTCT) in sub-Saharan Africa--a Delphi survey.

Authors:  Stella M Adegbehingbe; Virginia Paul-Ebhohimhen; Debbie Marais
Journal:  BMC Public Health       Date:  2012-06-06       Impact factor: 3.295

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.