Literature DB >> 17005583

Utility of exhaled nitric oxide as a noninvasive biomarker of lung inflammation in a disease model.

M A Birrell1, K McCluskie, E Hardaker, R Knowles, M G Belvisi.   

Abstract

There is a great deal of interest in developing less invasive markers for monitoring airway inflammation and the effect of possible novel anti-inflammatory therapies that may take time to impact on disease pathology. Exhaled nitric oxide (eNO) has been shown to be a reproducible, noninvasive indicator of the inflammatory status of the airway in the clinic. The aim of the present study was to determine the usefulness of measuring eNO as a marker of the anti-inflammatory impact of glucocorticoid and an inhibitor of kappaB kinase-2 (IKK-2) inhibitor 2-[(aminocarbonyl)amino]-5-(4-fluorophenyl)-3-thiophenecarboxamide (TPCA-1), in a pre-clinical model of airway inflammation. Rats were given vehicle, budesonide or TPCA-1 prior to exposure to lipopolysaccharide, previously shown to induce an increase in eNO and airway neutrophilia/eosinophilia. Comparison of the effect of the two compounds on inflammatory components demonstrated a significant correlation between the impact on eNO and inflammatory cell burden in the airway. The current study demonstrates the usefulness of profiling potential disease-modifying therapies on exhaled nitric oxide levels and the way in which an effect on this noninvasive biomarker relates to effects on pathological parameters such as lung cellularity. Information from studies such as the current one would suggest that the measurement of exhaled nitric oxide has potential for monitoring inflammatory status in lung tissue.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17005583     DOI: 10.1183/09031936.00048506

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  8 in total

Review 1.  Diabetes and immunity to tuberculosis.

Authors:  Nuria Martinez; Hardy Kornfeld
Journal:  Eur J Immunol       Date:  2014-02-16       Impact factor: 5.532

2.  Exhaled nitric oxide measurement to monitor pulmonary hypertension in a pneumonectomy-monocrotaline rat model.

Authors:  Magdalena Strobl; Catharina Schreiber; Adelheid Panzenböck; Max-Paul Winter; Helga Bergmeister; Johannes Jakowitsch; Julia Mascherbauer; Irene M Lang; Paul Wexberg; Diana Bonderman
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2013-07-26       Impact factor: 5.464

Review 3.  Mass casualties and health care following the release of toxic chemicals or radioactive material--contribution of modern biotechnology.

Authors:  Ann Göransson Nyberg; Daniela Stricklin; Åke Sellström
Journal:  Int J Environ Res Public Health       Date:  2011-12-07       Impact factor: 3.390

4.  Breath analysis using laser spectroscopic techniques: breath biomarkers, spectral fingerprints, and detection limits.

Authors:  Chuji Wang; Peeyush Sahay
Journal:  Sensors (Basel)       Date:  2009-10-19       Impact factor: 3.576

5.  Reversible ubiquitination shapes NLRC5 function and modulates NF-κB activation switch.

Authors:  Qingcai Meng; Chunmei Cai; Tingzhe Sun; Qianliang Wang; Weihong Xie; Rongfu Wang; Jun Cui
Journal:  J Cell Biol       Date:  2015-11-30       Impact factor: 10.539

6.  Associations between serum 25(OH)D concentrations and prevalent asthma among children living in communities with differing levels of urbanization: a cross-sectional study.

Authors:  Suzanne L Pollard; John J Lima; Karina Romero; Carla Tarazona-Meza; Edward Mougey; Katherine Tomaino; Gary Malpartida-Guzmán; Nadia N Hansel; William Checkley
Journal:  Asthma Res Pract       Date:  2017-06-02

7.  Reductions in biomarkers of exposure (BoE) to harmful or potentially harmful constituents (HPHCs) following partial or complete substitution of cigarettes with electronic cigarettes in adult smokers.

Authors:  Grant O'Connell; Donald W Graff; Carl D D'Ruiz
Journal:  Toxicol Mech Methods       Date:  2016-07-12       Impact factor: 2.987

Review 8.  Metal oxide-based gas sensors for the detection of exhaled breath markers.

Authors:  Fereshteh Vajhadin; Mohammad Mazloum-Ardakani; Abbas Amini
Journal:  Med Devices Sens       Date:  2021-03-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.