The reliability of the Auditory Steady State Response (ASSR) has not been thoroughly evaluated despite its recent application as a clinical tool for threshold estimation. The purpose of this study was to examine test-retest (TR) reliability of ASSR threshold estimates in an empirical research design. The ASSR, tested using modulation frequencies approximately 80 Hz and above, was evaluated against pure tone audiometry (PTA), and the slow vertex potential (SVP, N1-P2). Sixteen normal-hearing young female adults were tested twice, one week apart. Varying degrees of sensorineural hearing loss of a notched configuration were simulated with filtered masking noise. Test-retest reliability was assessed using Pearson-product moment correlation analysis, supplemented by other post-hoc analyses. Results demonstrated moderately strong TR reliability for ASSR at 1000, 2000 and 4000 Hz (r = 0.83-0.93); however, the reliability of ASSR at 500 Hz was weaker (r = 0.75). Results suggest that ASSR-ERA is a reliable test at mid-high frequencies, at least with the configuration and degrees of simulated sensorineural hearing loss examined in this study.

Entities:  

Mesh:

Year:  2006        PMID: 17005490     DOI: 10.1080/14992020600753197

Source DB:  PubMed          Journal:  Int J Audiol        ISSN: 1499-2027            Impact factor:   2.117


  5 in total

1.  [The problem of hearing threshold assessment in objective audiometry].

Authors:  U Hoppe
Journal:  HNO       Date:  2008-10       Impact factor: 1.284

2.  Converging evidence for gamma synchrony deficits in schizophrenia.

Authors:  B J Roach; J M Ford; R E Hoffman; D H Mathalon
Journal:  Suppl Clin Neurophysiol       Date:  2013

3.  Auditory steady state responses in normal-hearing and hearing-impaired adults: an analysis of between-session amplitude and latency repeatability, test time, and F ratio detection paradigms.

Authors:  Timothy S Wilding; Colette M McKay; Richard J Baker; Karolina Kluk
Journal:  Ear Hear       Date:  2012 Mar-Apr       Impact factor: 3.570

4.  Auditory steady state response in pediatric audiology.

Authors:  Ana Emilia Linares; Orozimbo Alves Costa Filho; Maria Angelina Nardi de Souza Martinez
Journal:  Braz J Otorhinolaryngol       Date:  2010 Nov-Dec

5.  Mode of recording and modulation frequency effects of auditory steady state response thresholds.

Authors:  Bahram Jalaei; Moslem Shaabani; Mohd Normani Zakaria
Journal:  Braz J Otorhinolaryngol       Date:  2016-03-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.