Literature DB >> 17003861

Tailored xerogel-based sensor arrays and artificial neural networks yield improved O2 detection accuracy and precision.

Ying Tang1, Zunyu Tao, Rachel M Bukowski, Elizabeth C Tehan, Sirisha Karri, Albert H Titus, Frank V Bright.   

Abstract

The objective of this research is to develop arrays of tuned chemical sensors wherein each sensor element responds to a particular target analyte in a unique manner. By creating sol-gel-derived xerogels that are co-doped with two luminophores at a range of molar ratios, we can form suites of sensor elements that can exhibit a continuum of response profiles. We trained an artificial neural network (ANN) to "learn" to identify the optical outputs from these xerogel-based sensor arrays. By using the ANN in concert with our tailored sensor arrays we obtained a 5-10 fold improvement in accuracy and precision for quantifying O2 in unknown samples. We also explored the response characteristics of these types of sensor elements after they had been contacted with rat plasma/blood. Contact with plasma/blood caused approximately 15% of the luminophore molecules within the xerogels to become non-responsive to O2. This behavior is consistent with rat albumin blocking certain pore sub-populations within the mesoporous xerogel matrix thereby limiting O2 access to the luminophores.

Entities:  

Year:  2006        PMID: 17003861     DOI: 10.1039/b604214g

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  4 in total

1.  Hybrid oxygen-responsive reflective Bragg grating platforms.

Authors:  Ka Yi Yung; Huina Xu; Ke Liu; Greggory J Martinez; Frank V Bright; Michael R Detty; Alexander N Cartwright
Journal:  Anal Chem       Date:  2012-01-12       Impact factor: 6.986

2.  CMOS Imaging of Pin-Printed Xerogel-Based Luminescent Sensor Microarrays.

Authors:  Lei Yao; Ka Yi Yung; Rifat Khan; Vamsy P Chodavarapu; Frank V Bright
Journal:  IEEE Sens J       Date:  2010-12       Impact factor: 3.301

3.  Contact CMOS imaging of gaseous oxygen sensor array.

Authors:  Daisy S Daivasagaya; Lei Yao; Ka Yi Yung; Mohamad Hajj-Hassan; Maurice C Cheung; Vamsy P Chodavarapu; Frank V Bright
Journal:  Sens Actuators B Chem       Date:  2011-10-01       Impact factor: 7.460

4.  Creating diversified response profiles from a single quenchometric sensor element by using phase-resolved luminescence.

Authors:  Elizabeth C Tehan; Rachel M Bukowski; Vamsy P Chodavarapu; Albert H Titus; Alexander N Cartwright; Frank V Bright
Journal:  Sensors (Basel)       Date:  2015-01-05       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.