Literature DB >> 17003821

Treatment of post-dialytic orthostatic hypotension with an inflatable abdominal band in hemodialysis patients.

N Yamamoto1, E Sasaki, K Goda, K Nagata, H Tanaka, J Terasaki, H Yasuda, A Imagawa, T Hanafusa.   

Abstract

The purpose of this study was to ascertain whether abdominal compression with an inflatable abdominal band, a device we developed, improved post-dialytic orthostatic hypotension (OH) in hemodialysis (HD) patients. Twenty-five chronic HD patients with intractable post-dialytic OH were recruited. Post-HD changes in systolic blood pressure (DeltaSBP) in the supine and standing positions were compared in the patients, measured with or without the use of the band. The study showed DeltaSBP after HD without the band was significantly greater than that measured before HD (-36.1+/-18.2 vs -13.1+/-16.8 mm Hg; P<0.0001). DeltaSBP after HD with the band was reduced significantly in comparison to DeltaSBP after HD without the band (-19.4+/-21.2 vs -36.1+/-18.2 mm Hg; P<0.002). Use of the band did not cause an elevation in SBP in the supine position (149.0+/-29.6 vs 155.4+/-25.7 mm Hg); however, it did increase SBP upon standing (129.6+/-27.3 vs 117.2+/-22.6 mm Hg; P<0.05). Eight patients in whom an increase in SBP of 25 mm Hg or more was achieved with the band were classified as responders. Ejection fraction was significantly higher (76.4+/-11.1 vs 61.9+/-13.6%; P<0.02) and atrial natriuretic peptide concentration significantly lower (27.9+/-22.0 vs 68.9+/-47.5 pg/ml; P<0.02) in responders than in non-responders. We conclude that the abdominal band was effective for overcoming post-dialytic OH, without elevating supine SBP in some patients.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17003821     DOI: 10.1038/sj.ki.5001852

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  2 in total

1.  Autoimmune autonomic ganglionopathy manifesting as acute-onset orthostatic hypotension in a patient undergoing peritoneal dialysis.

Authors:  Masatoshi Hara; Shunsuke Yamada; Yuuri Nakamura; Hideaki Oka; Taro Kamimura; Shunya Nakane; Kazuhiko Tsuruya; Atsumi Harada
Journal:  CEN Case Rep       Date:  2015-04-23

2.  Effects of the intermittent pneumatic circulator on blood pressure during hemodialysis.

Authors:  Tzu-Chao Hsu; Ya-Ju Chang; Yu-Yao Huang; Miao-Ju Hsu
Journal:  Sensors (Basel)       Date:  2010-11-09       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.