Literature DB >> 17003553

Does the source of laser energy influence the coagulation of chorionic plate vessels? Comparison of Nd:YAG and diode laser on an ex vivo placental model.

Jacky Nizard1, Jacques Patrick Barbet, Yves Ville.   

Abstract

OBJECTIVES: To compare the histological effects of diode and Neodymium-Yttrium Aluminium Garnet (Nd:YAG) laser coagulation of chorionic plate vessels.
METHODS: In selected chorionic plate vessels in an ex vivo term placenta perfused with warm saline solution, diode (wavelength 940 nm) and Nd:YAG (wave length 1,064 nm) laser were used with an output of 30, 40, and 50 W, and 55 and 70 W respectively using preset energy and duration of impact. All vessels were examined histologically blindly to the procedures' characteristics.
RESULTS: A total of 23 vessels were coagulated. Similar histological lesions were observed using diode and Nd:YAG lasers. The lesions were compatible with an acceptable clinical effect at all power outputs tested. The results were not related to the diameter or type of vessels. Lesions of the endothelium and reduction of the vessel lumen were best achieved with a diode laser at 40 W.
CONCLUSION: Nd:YAG and Diode laser induce significant and comparable changes in chorionic plate vessels compatible with an efficient coagulation process under the experimental condition used.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17003553     DOI: 10.1159/000095840

Source DB:  PubMed          Journal:  Fetal Diagn Ther        ISSN: 1015-3837            Impact factor:   2.587


  3 in total

1.  Impact of Laser Power and Firing Angle on Coagulation Efficiency in Laser Treatment for Twin-Twin Transfusion Syndrome: An ex vivo Placenta Study.

Authors:  Joost Akkermans; Loes van der Donk; Suzanne H P Peeters; Sjoerd van Tuijl; Johanna M Middeldorp; Enrico Lopriore; Dick Oepkes
Journal:  Fetal Diagn Ther       Date:  2017-03-29       Impact factor: 2.587

2.  Model Surgical Training: Skills Acquisition in Fetoscopic Laser Photocoagulation of Monochorionic Diamniotic Twin Placenta Using Realistic Simulators.

Authors:  Tuangsit Wataganara; Arundhati Gosavi; Katika Nawapun; Pradip D Vijayakumar; Nisarat Phithakwatchara; Mahesh Choolani; Lin Lin Su; Arijit Biswas; Citra N Z Mattar
Journal:  J Vis Exp       Date:  2018-03-21       Impact factor: 1.355

3.  Endoscopic diode laser therapy for chronic radiation proctitis.

Authors:  Lino Polese; Lucia Marini; Roberto Rizzato; Edgardo Picardi; Stefano Merigliano
Journal:  Lasers Med Sci       Date:  2017-09-11       Impact factor: 3.161

  3 in total