Literature DB >> 17003216

The contaminated high-energy open fracture: a protocol to prevent and treat inflammatory mediator storm-induced soft-tissue compartment syndrome (IMSICS).

Lawrence X Webb1, Barnaby Dedmond, Dan Schlatterer, David Laverty.   

Abstract

The treatment modalities currently used in surgical débridement leave the traumatic wound with viable but tenuous tissue and a variable level of microcontaminants potentially laden with bacteria. In high-energy contaminated wounds, retention of these contaminants within the tenuous tissue of the so-called zone of stasis can result in further tissue necrosis and the development of infection. A novel protocol for managing the high-energy contaminated open fracture involves two new techniques. First, Bernoulli's principle is used to facilitate a systematic excision of contaminants, as well as the wound surface to which they are adsorbed, by means of a high-velocity fluid stream. Second, topical negative pressure is established as a means to resuscitate the remaining edema-laden wound tissue to help avoid embarrassment to microcirculatory blood flow.

Entities:  

Mesh:

Year:  2006        PMID: 17003216     DOI: 10.5435/00124635-200600001-00019

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   3.020


  6 in total

Review 1.  Negative pressure wound therapy in grade IIIB tibial fractures: fewer infections and fewer flap procedures?

Authors:  Daniel R Schlatterer; Adam G Hirschfeld; Lawrence X Webb
Journal:  Clin Orthop Relat Res       Date:  2015-01-17       Impact factor: 4.176

2.  Non-invasive assessment of negative pressure wound therapy using high frequency diagnostic ultrasound: oedema reduction and new tissue accumulation.

Authors:  Stephen R Young; Sylvie Hampton; Robin Martin
Journal:  Int Wound J       Date:  2012-06-04       Impact factor: 3.315

3.  The evidence-based principles of negative pressure wound therapy in trauma & orthopedics.

Authors:  Novak A; Wasim S Khan; Palmer J
Journal:  Open Orthop J       Date:  2014-06-27

4.  In-hospital low-cost custom made VAC: Effective method for reducing infection in late presenting Open lower limb fractures in overburdened Indian hospitals.

Authors:  Towseef Ahmad Bhat; Rouf Ibrahim; Tariq Ahmad Bhat; Aejaz Ahmad Bhat
Journal:  J Clin Orthop Trauma       Date:  2017-11-24

5.  Synergistic Effect of Mesoporous Silica and Hydroxyapatite in Loaded Poly(DL-lactic-co-glycolic acid) Microspheres on the Regeneration of Bone Defects.

Authors:  Shu He; Kai-Feng Lin; Jun-Jun Fan; Gang Hu; Xin Dong; Yi-Nan Zhao; Yue Song; Zhong-Shang Guo; Long Bi; Jian Liu
Journal:  Biomed Res Int       Date:  2016-08-29       Impact factor: 3.411

6.  Simplified negative pressure wound therapy: clinical evaluation of an ultraportable, no-canister system.

Authors:  Donald A Hudson; Kevin G Adams; Adriaan Van Huyssteen; Robin Martin; Elizabeth M Huddleston
Journal:  Int Wound J       Date:  2013-05-07       Impact factor: 3.315

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.