Literature DB >> 17002743

Prosthetic complications in fixed endosseous implant-borne reconstructions after an observations period of at least 40 months.

A L De Boever1, K Keersmaekers, G Vanmaele, T Kerschbaum, G Theuniers, J A De Boever.   

Abstract

One hundred and seventy-two fixed reconstructions (317 prosthetic units), made on 283 ITI implants in 105 patients (age range 25-86 years) with a minimum follow-up period of 40 months, were taken into the study to analyse technical complication rate, complication type and costs for repair. The mean evaluation time was 62.5 +/- 25.3 months. Eighty were single crowns and 92 different types of fixed partial dentures (FPDs). In 45 cases the construction was screw retained and in 127 cases cemented with zinc phosphate cement or an acrylic-based cement. Complications occurred after a minimum period of 2 months and a maximum period of 100 months (mean: 35.9 +/- 21.4 months). Fifty-five prosthetic interventions were needed on 44 constructions (25%) of which 88% in the molar/premolar region. The lowest percentage of complications occurred in single crowns (25%), the highest in 3-4 unit FPDs (35%) and in FPDs with an extension (44%). Of the necessary clinical repair, 36% was recementing and 38% tightening the screws. Of all interventions, 14% were classified as minor (no treatment or <10 min chair time), 70% as moderate (>10 min but <60 min chair time) and 14% as major interventions (>60 min and additional costs for replacement of parts and/or laboratory). For seven patients the additional costs ranged from euro 28 to euro 840. Bruxing seemed to play a significant role in the frequency of complications. Longer constructions seemed to be more prone to complications. The relatively high occurrence of technical complications should be discussed with the patient before the start of the treatment.

Entities:  

Mesh:

Year:  2006        PMID: 17002743     DOI: 10.1111/j.1365-2842.2006.01638.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  7 in total

1.  Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts.

Authors:  Judy Chia-Chun Yuan; Cortino Sukotjo
Journal:  J Periodontal Implant Sci       Date:  2013-04-30       Impact factor: 2.614

2.  Influence of abutment design on retention of metal copings cemented to implants.

Authors:  Albano Porto da Cunha; Glauco Pereira Moysés; Ana Christina Claro Neves; Rafael Pino Vitti; Flávia Cardoso da Rosa Goulart; Laís Regiane da Siva-Concílio
Journal:  Acta Biomater Odontol Scand       Date:  2016-01-26

Review 3.  Retention failures in cement- and screw-retained fixed restorations on dental implants in partially edentulous arches: A systematic review with meta-analysis.

Authors:  Jatin K Jain; Rajesh Sethuraman; Sameer Chauhan; Piyush Javiya; Shreya Srivastava; Rutvik Patel; Bhagyashri Bhalani
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

4.  Dimensional Changes of 3-Unit Implant-Supported Zirconia Frameworks of Two CAD/CAM Systems from Scanning to Sintering.

Authors:  Marzieh Alikhasi; Narges Ameri; Hakimeh Siadat; Ahmad Reza Shamshiri; Mohammadreza Nejati
Journal:  Front Dent       Date:  2019-06-29

5.  Variability of sleep bruxism-findings from consecutive nights of monitoring.

Authors:  Brigitte Ohlmann; Wolfgang Bömicke; Rouven Behnisch; Peter Rammelsberg; Marc Schmitter
Journal:  Clin Oral Investig       Date:  2021-12-03       Impact factor: 3.573

Review 6.  An Overview of the Mechanical Integrity of Dental Implants.

Authors:  Keren Shemtov-Yona; Daniel Rittel
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

7.  Complications of Fixed Full-Arch Implant-Supported Metal-Ceramic Prostheses.

Authors:  Ignacio Gonzalez-Gonzalez; Hector deLlanos-Lanchares; Aritza Brizuela-Velasco; Jose-Antonio Alvarez-Riesgo; Santiago Llorente-Pendas; Mariano Herrero-Climent; Angel Alvarez-Arenal
Journal:  Int J Environ Res Public Health       Date:  2020-06-14       Impact factor: 3.390

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.