Literature DB >> 17002742

Fracture load and marginal fit of shrinkage-free ZrSiO4 all-ceramic crowns after chewing simulation.

M Okutan1, G Heydecke, F Butz, J R Strub.   

Abstract

The aim of this in vitro study was to evaluate the fracture load and marginal accuracy of crowns made from a shrinkage-free ZrSiO4 ceramic cemented with glass-ionomer or composite cement after chewing simulation. Thirty-two human mandibular molars were randomly divided into two groups. All teeth were prepared for and restored with shrinkage-free ZrSiO4 ceramic crowns (Everest HPC, KaVo). The crowns of group A (N = 16) were luted to the teeth using KetacCem and group B (N = 16) were adhesively cemented using Panavia21EX. Measurements of the marginal accuracy before and after cementation were made using replicas and an image analysis system. All specimens were exposed to 1.2 million cycles of thermo-mechanical fatigue in a chewing simulator. Surviving specimens were subsequently loaded until fracture in a static testing device. Fracture loads (N) were recorded. All specimens survived chewing simulation. The mean fracture loads (+/-s.d.) were Group A, 1622 N (+/-433); group B, 1957 N (+/-806). There was no significant difference between the two groups (P > 0.05). The marginal gap values before cementation were (mean +/- s.d.): Group A, 32.7 microm (+/-6.8); group B, 33.0 microm (+/-6.7). The mean marginal gap values after cementation were (+/-s.d.): Group A, 44.6 microm (+/-6.7); group B, 46.6 microm (+/-7.7). The marginal openings were significantly higher after cementation for both groups (P < 0.05). All test groups demonstrated fracture load and marginal accuracy values within the range of clinical acceptability.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17002742     DOI: 10.1111/j.1365-2842.2006.01637.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  4 in total

1.  Effect of Resin Bonded Luting Agents Influencing Marginal Discrepancy in All Ceramic Complete Veneer Crowns.

Authors:  Dhanraj Ganapathy; Anusha Sathyamoorthy; Hemalatha Ranganathan; Karthikeyan Murthykumar
Journal:  J Clin Diagn Res       Date:  2016-12-01

2.  In vitro evaluation of the effect of core thickness and fabrication stages on the marginal accuracy of an all-ceramic system.

Authors:  F Farid; H Hajimiragha; R Jelodar; A S Mostafavi; H Nokhbatolfoghahaie
Journal:  J Dent (Tehran)       Date:  2012-09-30

3.  An Advanced Fiber-Reinforced Composite Solution for Gingival Inflammation and Bone Loss Related to Restorative Crowns.

Authors:  Richard C Petersen; Perng-Ru Liu; Michael S Reddy
Journal:  EC Dent Sci       Date:  2020-01-29

4.  Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems.

Authors:  Tae-Jin Song; Taek-Ka Kwon; Jae-Ho Yang; Jung-Suk Han; Jai-Bong Lee; Sung-Hun Kim; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.