Literature DB >> 17002739

Reproducibility of jaw movements in patients with craniomandibular disorders.

M Stiesch-Scholz1, A Demling, A Rossbach.   

Abstract

It has never been investigated, if mandibular movements of patients with craniomandibular disorders (CMD) result in a lower reproducibility of dynamic functional parameters which are used for the individual articulator setting. The aim of the present study was to compare the reproducibility of electronically registered functional parameters in patients with CMD and in a control group. Dynamic functional parameters were recorded in 30 patients and 30 volunteers with a computerized ultrasound system (ARCUSdigma). The whole registration was performed three times during one session and three times at a second session 1 week later. The horizontal condylar inclination in the patient group gave a standard deviation of 2.17 degrees +/- 0.95 degrees , indicating poorer reproducibility than in the volunteer group, for which the standard deviation was 1.37 degrees +/- 0.42 degrees . The reproducibility of measurements of the Bennett angle was also poorer in the patient group than in the volunteer group, with standard deviations of 1.70 degrees +/- 0.62 degrees and 1.22 degrees +/- 0.40 degrees , respectively. The standard deviations calculated for determination of incisal inclination during laterotrusion was 3.02 degrees +/- 1.49 degrees for patients and 2.30 degrees +/- 1.17 degrees for volunteers. The standard deviations for incisal inclination during protrusion was 2.02 degrees +/- 0.95 degrees for patients and 2.06 degrees +/- 1.82 degrees for volunteers. The reproducibility of measurement of horizontal condylar inclination, Bennett angle and incisal inclination during laterotrusion therefore showed significantly lower reproducibility in the patient group than in the volunteer group (P < 0.05). The overall reproducibility of the measurements was nevertheless good in both groups, with standard deviations under 3.1 degrees , so that an individual setting of an articulator seems useful even in patients with CMD.

Entities:  

Mesh:

Year:  2006        PMID: 17002739     DOI: 10.1111/j.1365-2842.2006.01636.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  7 in total

1.  Influence of Occlusal Splint on Mandibular Movements in Patients with Bruxism: a Comparative Pilot Study.

Authors:  Josip Škaričić; Samir Čimić; Sonja Kraljević-Šimunković; Marko Vuletić; Nikša Dulčić
Journal:  Acta Stomatol Croat       Date:  2020-09

2.  Bennett movement of mandible: a comparison between traditional methods and a 64-slices CT scanner.

Authors:  E Fanucci; E Spera; L Ottria; A Barlattani; N Fusco; I Mylonakou; P Broccoli; A Barlattani; G Simonetti
Journal:  Oral Implantol (Rome)       Date:  2008-06-16

3.  Comparison of Parameters for Programming Adjustable Dental Articulators by Using Wax Eccentric Records and Arcus Digma Device.

Authors:  Kristina Mage; Robert Ćelić; Samir Ćimić; Nikša Dulčić
Journal:  Acta Stomatol Croat       Date:  2019-09

Review 4.  Efficacy of Kinematic Parameters for Assessment of Temporomandibular Joint Function and Disfunction: A Systematic Review and Meta-Analysis.

Authors:  Alessandra Scolaro; Shahnawaz Khijmatgar; Pooja Mali Rai; Francesca Falsarone; Francesca Alicchio; Arianna Mosca; Christian Greco; Massimo Del Fabbro; Gianluca Martino Tartaglia
Journal:  Bioengineering (Basel)       Date:  2022-06-22

5.  Changes in Maximum Mandibular Mobility Due to Splint Therapy in Patients with Temporomandibular Disorders.

Authors:  Bernhard Wiechens; Svea Paschereit; Tristan Hampe; Torsten Wassmann; Nikolaus Gersdorff; Ralf Bürgers
Journal:  Healthcare (Basel)       Date:  2022-06-09

6.  Comparison of selected kinematic facebows applied to mandibular tracing.

Authors:  Mieszko Wieckiewicz; Marek Zietek; Danuta Nowakowska; Wlodzimierz Wieckiewicz
Journal:  Biomed Res Int       Date:  2014-05-07       Impact factor: 3.411

7.  Reproducibility of the Obtained Centric Relation Records in Patients with Disc Displacement with Reduction.

Authors:  Samir Čimić; Sonja Kraljević Šimunković; Ana Savić Mlakar; Sunčana Simonić Kocijan; Petra Tariba; Amir Ćatić
Journal:  Acta Stomatol Croat       Date:  2018-03
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.