Mathematical explanation of the buckling of the vessels after twisting of the microanastomosis.

G Selvaggi1, S Anicic, L Formaggia.   

Abstract

BACKGROUND: To obtain free flap success, microvascular anastomosis must be perfectly constructed. External compression, twisting (torsion) of the anastomosis site, tension on the anastomosis site, and kinking of the pedicle must be avoided. Few experimental studies report the patency rates of rat vessels after twisting (torsion) of the microanastomosis: these results recently opened a discussion for the maximal angle of torsion, which can be impressed to a vessel in order to have the best patency rates.
MATERIALS AND METHODS: To describe specifically the changing of shape of the vessels after the twisting of the microanastomosis, we extrapolate, to our experimental model (constituted by the femoral vessels of Wistar rats), the mathematical formula that engineers use to calculate the torsion of a beam when a torsion force is applied. The mathematical model used is the shell theory. Then, with a computer program using MATLAB, we could obtain the representation of these shapes at any degree of torsion.
RESULTS: If a small load is applied to the vessels, it maintains its straight geometry. However, as soon as the load exceeds a critical value, which is a function of the vessel geometry and its mechanical characteristics, it snaps suddenly to a different equilibrium configuration. This phenomenon is called "buckling." When buckling occurs, wave-like deformations appear on the wall of the vessels. We calculate, in our experimental rat model, the critical twisting angle that induces buckling: maintaining a constant length of dissection of 25 mm, a minimum twisting angle of 360 degrees + 161 degrees, or 105 degrees, is required, respectively, for the femoral artery or vein, to have the buckling phenomenon and the appearance of two waves and decreased section area.
CONCLUSIONS: In surgical practice, with the parameters of our experimental Wistar rats model (vessel diameter, length of dissection), it is fundamental to be below 105 degrees of torsion angle for the vein microanastomosis, in order to decrease its risk of failure. (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 17001640     DOI: 10.1002/micr.20281

Source DB:  PubMed          Journal:  Microsurgery        ISSN: 0738-1085            Impact factor:   2.425


  10 in total

Review 1.  Complications and Solutions in Propeller Flap Surgery.

Authors:  Marta Cajozzo; Lucian P Jiga; Zaher Jandali; Mismil Muradov; Marco Pignatti; Adriana Cordova; Salvatore D'Arpa
Journal:  Semin Plast Surg       Date:  2020-09-22       Impact factor: 2.314

Review 2.  Perforator-Pedicled Propeller Flaps for Lower Extremity Reconstruction.

Authors:  Mohamed A Ellabban; Ahmed I Awad; Geoffrey G Hallock
Journal:  Semin Plast Surg       Date:  2020-09-22       Impact factor: 2.314

3.  Mechanical behavior and wall remodeling of blood vessels under axial twist.

Authors:  Hai-Chao Han; Qin Liu; Zong-Lai Jiang
Journal:  Yi Yong Sheng Wu Li Xue       Date:  2016-08

4.  Twist buckling of veins under torsional loading.

Authors:  Justin R Garcia; Arnav Sanyal; Fatemeh Fatemifar; Mohammad Mottahedi; Hai-Chao Han
Journal:  J Biomech       Date:  2017-05-05       Impact factor: 2.712

5.  Computational simulations of the helical buckling behavior of blood vessels.

Authors:  Mohammadali Sharzehee; Fatemeh Fatemifar; Hai-Chao Han
Journal:  Int J Numer Method Biomed Eng       Date:  2019-11-27       Impact factor: 2.747

6.  Are there risk factors for complications of perforator-based propeller flaps for lower-extremity reconstruction?

Authors:  Marco Innocenti; Giulio Menichini; Carla Baldrighi; Luca Delcroix; Livia Vignini; Pierluigi Tos
Journal:  Clin Orthop Relat Res       Date:  2014-04-05       Impact factor: 4.176

Review 7.  Propeller flaps: a review of indications, technique, and results.

Authors:  Salvatore D'Arpa; Francesca Toia; Roberto Pirrello; Francesco Moschella; Adriana Cordova
Journal:  Biomed Res Int       Date:  2014-05-26       Impact factor: 3.411

8.  Peroneal perforator pedicle propeller flap for lower leg soft tissue defect reconstruction: Clinical applications and treatment of venous congestion.

Authors:  Lifeng Shen; Yiyang Liu; Chun Zhang; Qiaofeng Guo; Wenhua Huang; Kelvin Kian Loong Wong; Shimin Chang
Journal:  J Int Med Res       Date:  2017-03-27       Impact factor: 1.671

9.  Perforator relocation in free style local perforator flaps.

Authors:  Nikhil Panse; Parag Sahasrabudhe; Namrata Joshi
Journal:  World J Plast Surg       Date:  2013-01

10.  Combined versus Single Perforator Propeller Flaps for Reconstruction of Large Soft Tissue Defects: A Retrospective Clinical Study.

Authors:  Amir K Bigdeli; Oliver Didzun; Benjamin Thomas; Leila Harhaus; Emre Gazyakan; Raymund E Horch; Ulrich Kneser
Journal:  J Pers Med       Date:  2022-01-04