Literature DB >> 17001576

Autologous fibrin sealant (Vivostat) for mesh fixation in laparoscopic transabdominal preperitoneal hernia repair.

S C Schmidt1, J M Langrehr.   

Abstract

BACKGROUND AND STUDY AIMS: The use of fibrin glue derived from humans or animals has been reported as an alternative method of mesh fixation, instead of staples, in inguinal hernia repair. However, fibrin sealants involve the potential risks of virus transmission or immunological reactions to foreign proteins. This risk could be avoided by using autologous fibrin derived from the patient. A feasibility study on the use of autologous fibrin was therefore carried out in patients undergoing laparoscopic transabdominal inguinal hernia repair. PATIENTS AND METHODS: In a series of 10 patients undergoing laparoscopic transabdominal inguinal hernia repair, autologous fibrin was produced from 120 ml of the patient's blood during the hernia repair. The process took an average of 20 min. The perioperative and postoperative results were compared with those in a control group of 20 patients in whom conventional fibrin was used.
RESULTS: Producing and applying the autologous fibrin was uncomplicated. No differences in the outcome were observed between the two groups. One patient in the conventional fibrin group developed a seroma. None of the patients reported persistent pain. No recurrences were observed after a mean follow-up period of 9 months (range 6 - 12 months) in the conventional fibrin group and 7 months (range 6 - 8 months) in the autologous fibrin group.
CONCLUSIONS: This feasibility study suggests that autologous fibrin sealant allowed adequate mesh fixation that did not differ from that in a control group in whom conventional fibrin glue was used. Autologous fibrin may be an interesting alternative for a variety of laparoscopic and endoscopic applications.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17001576     DOI: 10.1055/s-2006-944609

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  3 in total

1.  Pain after laparascopic bilateral hernioplasty : Early results of a prospective randomized double-blind study comparing fibrin versus staples.

Authors:  E Boldo; Andres Armelles; Guillermo Perez de Lucia; Felix Martin; Juan Pablo Aracil; Juan Manuel Miralles; David Martinez; Javier Escrig
Journal:  Surg Endosc       Date:  2007-10-18       Impact factor: 4.584

2.  Autologous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part I: Intracranial surgical procedure.

Authors:  Francesca Graziano; Francesco Certo; Luigi Basile; Rosario Maugeri; Giovanni Grasso; Flavia Meccio; Mario Ganau; Domenico G Iacopino
Journal:  Surg Neurol Int       Date:  2015-05-12

3.  Aulogous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part II: Vertebro-spinal procedures.

Authors:  Francesca Graziano; Rosario Maugeri; Luigi Basile; Favia Meccio; Domenico Gerardo Iacopino
Journal:  Surg Neurol Int       Date:  2016-01-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.