Literature DB >> 16999759

FACS technology used in a new rapid bacterial detection method.

M Schmidt1, M K Hourfar, S-B Nicol, H-P Spengler, T Montag, Erhard Seifried.   

Abstract

Culture methods for bacterial detection (BacT/ALERT or Pall eBDS) are currently implemented in blood donor screening procedures in many countries. Experience in the first years after implementation of these detection assays showed that although the analytical sensitivity was extremely high (about 1 CFU mL(-1)), the majority of these platelets were still transfused before a positive screening result was attained. Rapid technologies were developed to more effectively prevent transfusion-transmitted bacterial infection. In this study, a new rapid bacterial detection method based on fluorescence-activated cell sorting (FACS) technology was developed. Bacteria were stained with thiazole orange dye for 5 min and measurement was taken immediately after staining. The entire process took only 30 min. Six transfusion-relevant bacteria strains were tested in a spiking study. Without pre-incubation in a special bacteria growth medium, analytical sensitivity ranged between 10(5) CFU mL(-1) (Klebsiella oxytoca and Serratia marcesens) and 10(3) CFU mL(-1) (Escherichia coli). Sensitivity could be improved to 10(1) CFU mL(-1) for all tested bacteria by adding a pre-incubation step (6 h at 37 degrees C). Although preliminary in nature, results of our study suggest that bacterial detection by FACS technology in conjunction with a pre-incubation step offers a sensitive alternative technology to culture methods. Additionally, it provides the benefit of a rapid test time and the opportunity of preventing bacterial transmitted infections more effectively.

Entities:  

Mesh:

Year:  2006        PMID: 16999759     DOI: 10.1111/j.1365-3148.2006.00686.x

Source DB:  PubMed          Journal:  Transfus Med        ISSN: 0958-7578            Impact factor:   2.019


  4 in total

1.  Experimental use of flow cytometry to detect bacteria viability after hyperbaric oxygen exposure: Work in progress report.

Authors:  Miroslav Rozloznik; Alexandra Lochmanova; Dittmar Chmelar; Michal Hajek; Karin Korytkova; Monika Cisarikova
Journal:  Diving Hyperb Med       Date:  2020-06-30       Impact factor: 0.887

2.  Implementation of Bacterial Detection Methods into Blood Donor Screening - Overview of Different Technologies.

Authors:  Michael Schmidt; Walid Sireis; Erhard Seifried
Journal:  Transfus Med Hemother       Date:  2011-07-07       Impact factor: 3.747

3.  Feasibility of flow cytometry for measurements of Plasmodium falciparum parasite burden in studies in areas of malaria endemicity by use of bidimensional assessment of YOYO-1 and autofluorescence.

Authors:  Joseph J Campo; John J Aponte; Augusto J Nhabomba; Jahit Sacarlal; Iñigo Angulo-Barturen; María Belén Jiménez-Díaz; Pedro L Alonso; Carlota Dobaño
Journal:  J Clin Microbiol       Date:  2011-01-12       Impact factor: 5.948

4.  The Pan Genera Detection immunoassay: a novel point-of-issue method for detection of bacterial contamination in platelet concentrates.

Authors:  Tanja Vollmer; Dennis Hinse; Knut Kleesiek; Jens Dreier
Journal:  J Clin Microbiol       Date:  2010-08-11       Impact factor: 5.948

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.