Literature DB >> 16995453

Four-dimensional ultrasonography for therapeutic radiofrequency ablation for hepatocellular carcinoma.

Naoki Hotta1, Tadashi Maeno, Minoru Ayada, Ken Sato, Tetsuya Ishikawa, Akihiko Okumura, Eiji Matsumoto, Yoshitaka Fukuzawa, Shinichi Kakumu.   

Abstract

BACKGROUND/AIMS: We examined whether four-dimensional real-time flow imaging on ultrasonography (US) is valuable to display the accurate position of percutaneous radiofrequency ablation (RFA) needle in the nodule of hepatocellular carcinoma (HCC).
METHODOLOGY: Ten patients with 12 HCC nodules were studied; nine were infected with hepatitis C virus (HCV) and one was diagnosed as non-B non-C. Diagnosis was done by helical dynamic CT and/or celiac angiography. Tumor vascularities in the early arterial and post-vascular phases after injection of a microbubble contrast agent were assessed by real-time US scanning of coded harmonic imaging and intermittent interval-delay scanning with a wide-band power Doppler technology. Percutaneous RFA was performed with four-dimensional real-time flow imaging under US to display the accurate position of cool-tip needle.
RESULTS: It was possible to obtain accurate position of the needle during RFA procedure in all 12 nodules. The needle was confirmed to be inserted into the center of the tumor nodule by various angles. The simultaneous study before RFA therapy showed the inflow of arterial blood and tumor staining in all nodules at early arterial phase of coded harmonic angio on contrast-enhanced US scan. Posttreatment study to evaluate the therapeutic efficacy showed no blood flow at both early vascular and post-vascular phases. No residual blood flow was noted on early phase of CT scan with adequate safety margin. There was no discrepancy in the finding at early phase between contrast-enhanced US and dynamic CT.
CONCLUSIONS: It appeared that four-dimensional real-time US provided more perceptible information on the spatial relationship between RFA needle and the target lesion, and resulted in accurate therapeutic efficacy for percutaneous RFA procedure.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16995453

Source DB:  PubMed          Journal:  Hepatogastroenterology        ISSN: 0172-6390


  3 in total

1.  Case-control study of the RFA therapeutic effect of newly developed 4D US and conventional 2D US.

Authors:  Atsunori Kusakabe; Shunsuke Nojiri; Etsuko Iio; Kentaro Matsuura; Noboru Shinkai; Tomokatsu Miyaki; Takashi Joh
Journal:  J Med Ultrason (2001)       Date:  2012-07-31       Impact factor: 1.314

2.  Image-guided tumor ablation: emerging technologies and future directions.

Authors:  Justin P McWilliams; Edward W Lee; Shota Yamamoto; Christopher T Loh; Stephen T Kee
Journal:  Semin Intervent Radiol       Date:  2010-09       Impact factor: 1.513

3.  Usefulness of Real-Time 4D Ultrasonography during Radiofrequency Ablation in a Case of Hepatocellular Carcinoma.

Authors:  Naoki Hotta; Seigo Yamada; Kenichi Murase; Kazuo Masuko
Journal:  Case Rep Gastroenterol       Date:  2011-02-01