Literature DB >> 16990676

Pancreas: optimal scan delay for contrast-enhanced multi-detector row CT.

Satoshi Goshima1, Masayuki Kanematsu, Hiroshi Kondo, Ryujiro Yokoyama, Toshiharu Miyoshi, Hiroki Kato, Yusuke Tsuge, Yoshimune Shiratori, Hiroaki Hoshi, Minoru Onozuka, Noriyuki Moriyama, Kyongtae T Bae.   

Abstract

PURPOSE: To prospectively determine optimal scan delays for multiphasic contrast medium-enhanced imaging of the pancreas with multi-detector row computed tomography (CT).
MATERIALS AND METHODS: This study was approved by an institutional review committee, and patients gave written informed consent. One hundred ninety-one patients underwent three-phase CT of the pancreas after receiving intravenous contrast medium with a fixed duration injection of 30 seconds. Patients were prospectively assigned among four groups with scan delays of 25, 45, and 65 seconds (group 1); 30, 50, and 70 seconds (group 2); 35, 55, and 75 seconds (group 3); and 40, 60, and 80 seconds (group 4). Mean CT numbers of abdominal aorta, spleen, pancreatic parenchyma, superior mesenteric artery and vein, splenic vein, and hepatic parenchyma were measured, and increases in contrast enhancement on enhanced images were assessed. Qualitative analysis was performed with a four-point scale.
RESULTS: Abdominal aorta and superior mesenteric artery enhanced at a mean of 35 seconds from the start of injection (both P < .001). Pancreatic parenchyma enhanced most intensely at 35-45 seconds (P < .001) with a peak enhancement at the mean of 40 seconds. Liver parenchyma enhanced most intensely at 55-65 seconds with a peak at 60 seconds (P < .001). The mean time to peak enhancement was 45 seconds for the splenic vein and 55 seconds for the superior mesenteric vein. Qualitative results were in good agreement with quantitative results (both P < .001).
CONCLUSION: With the injection protocol used in this study, optimal scan delays for imaging the pancreas were 30-35 seconds for the abdominal aorta and the superior mesenteric artery, 35-45 seconds for the pancreas, 45 seconds for the splenic vein, and 55 seconds or later for the liver. (c) RSNA, 2006.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16990676     DOI: 10.1148/radiol.2411051338

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  10 in total

Review 1.  Pancreatic neoplasia: a practical cross-sectional imaging primer for the nonradiologist.

Authors:  Matthew T Heller; Nathan Johnson; Antonio Fargiano
Journal:  J Gastrointest Cancer       Date:  2012-06

2.  Sixty-four MDCT achieves higher contrast in pancreas with optimization of scan time delay.

Authors:  Tina Stuber; Hans-Jürgen Brambs; Wolfgang Freund; Markus S Juchems
Journal:  World J Radiol       Date:  2012-07-28

3.  Dual-source, dual-energy multidetector CT for the evaluation of pancreatic tumours.

Authors:  A J Chu; J M Lee; Y J Lee; S K Moon; J K Han; B I Choi
Journal:  Br J Radiol       Date:  2012-10       Impact factor: 3.039

4.  64-section multidetector CT of the upper abdomen: optimization of a saline chaser injection protocol for improved vascular and parenchymal contrast enhancement.

Authors:  Daniele Marin; Rendon C Nelson; Antonino Guerrisi; Huiman Barnhart; Sebastian T Schindera; Roberto Passariello; Carlo Catalano
Journal:  Eur Radiol       Date:  2011-05-11       Impact factor: 5.315

5.  Individually optimized contrast-enhanced 4D-CT for radiotherapy simulation in pancreatic ductal adenocarcinoma.

Authors:  Wookjin Choi; Ming Xue; Barton F Lane; Min Kyu Kang; Kruti Patel; William F Regine; Paul Klahr; Jiahui Wang; Shifeng Chen; Warren D'Souza; Wei Lu
Journal:  Med Phys       Date:  2016-10       Impact factor: 4.071

Review 6.  Circumportal pancreas: a clinicoradiological and embryological review.

Authors:  Ankur Arora; Prabhakaran Velayutham; S Rajesh; Yashwant Patidar; Amar Mukund; Kishore G S Bharathy
Journal:  Surg Radiol Anat       Date:  2013-08-27       Impact factor: 1.246

Review 7.  Imaging diagnosis of pancreatic cancer: a state-of-the-art review.

Authors:  Eun Sun Lee; Jeong Min Lee
Journal:  World J Gastroenterol       Date:  2014-06-28       Impact factor: 5.742

8.  Automatic bolus tracking versus fixed time-delay technique in biphasic multidetector computed tomography of the abdomen.

Authors:  Atoosa Adibi; Ali Shahbazi
Journal:  Iran J Radiol       Date:  2014-01-30       Impact factor: 0.212

9.  Optimized scan delay for late hepatic arterial or pancreatic parenchymal phase in dynamic contrast-enhanced computed tomography with bolus-tracking method.

Authors:  Yoshifumi Noda; Nobuyuki Kawai; Takuma Ishihara; Yoshiki Tsuboi; Tetsuro Kaga; Toshiharu Miyoshi; Fuminori Hyodo; Masayuki Matsuo
Journal:  Br J Radiol       Date:  2021-05-06       Impact factor: 3.629

10.  Whole-organ CT perfusion of the pancreas: impact of iterative reconstruction on image quality, perfusion parameters and radiation dose in 256-slice CT-preliminary findings.

Authors:  Qian Xie; Juan Wu; Ying Tang; Yafang Dou; Sijie Hao; Feijia Xu; Xiaoyuan Feng; Zonghui Liang
Journal:  PLoS One       Date:  2013-11-26       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.