Literature DB >> 16990231

A functional evaluation of prosthetic foot kinematics during lower-limb amputee gait.

H Goujon1, X Bonnet, P Sautreuil, M Maurisset, L Darmon, P Fode, F Lavaste.   

Abstract

This paper reports on a functional evaluation of prosthetic feet based on gait analysis. The aim is to analyse prosthetic feet behaviour under loads applied during gait in order to quantify user benefits for each foot. Ten traumatic amputees (six trans-tibial and four trans-femoral) were tested using their own prosthetic foot. An original protocol is presented to calculate the forefoot kinematics together with the overall body kinematics and ground reaction forces during gait. In this work, sagittal motion of the prosthetic ankle and the forefoot, time-distance parameters and ground reaction forces were examined. It is shown that an analysis of not only trans-tibial but also trans-femoral amputees provides an insight in the performance of prosthetic feet. Symmetry and prosthetic propulsive force were proved to be mainly dependant on amputation level. In contrast, the flexion of the prosthetic forefoot and several time-distance parameters are highly influenced by foot design. Correlations show influential of foot and ankle kinematics on other parameters. These results suggest that prosthetic foot efficiency depends simultaneously on foot design and gait style. The evaluation, proposed in this article, associated to clinical examination should help to achieve the best prosthetic foot match to a patient.

Entities:  

Mesh:

Year:  2006        PMID: 16990231     DOI: 10.1080/03093640600805134

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  6 in total

Review 1.  The KneeKG system: a review of the literature.

Authors:  Sébastien Lustig; Robert A Magnussen; Laurence Cheze; Philippe Neyret
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-04       Impact factor: 4.342

2.  Gait event detection using inertial measurement units in people with transfemoral amputation: a comparative study.

Authors:  Emeline Simonetti; Coralie Villa; Joseph Bascou; Giuseppe Vannozzi; Elena Bergamini; Hélène Pillet
Journal:  Med Biol Eng Comput       Date:  2019-12-23       Impact factor: 2.602

3.  Kinetic Gait Parameters in Unilateral Lower Limb Amputations and Normal Gait in Able-Bodied: Reference Values for Clinical Application.

Authors:  Karin Schmid-Zalaudek; Theresa Fischer; Zoltán Száva; Helmut Karl Lackner; Ursula Kropiunig; Christian Bittner; Karl Höcker; Günther Winkler; Gerfried Peternell
Journal:  J Clin Med       Date:  2022-05-10       Impact factor: 4.964

4.  Gait biomechanics of individuals with transtibial amputation: effect of suspension system.

Authors:  Arezoo Eshraghi; Noor Azuan Abu Osman; Mohammad Karimi; Hossein Gholizadeh; Ehsan Soodmand; Wan Abu Bakar Wan Abas
Journal:  PLoS One       Date:  2014-05-27       Impact factor: 3.240

5.  STEPFORWARD study: a randomised controlled feasibility trial of a self-aligning prosthetic ankle-foot for older patients with vascular-related amputations.

Authors:  Natalie Vanicek; Elizabeth Coleman; Judith Watson; Kerry Bell; Catriona McDaid; Cleveland Barnett; Martin Twiste; Fergus Jepson; Abayomi Salawu; Dennis Harrison; Natasha Mitchell
Journal:  BMJ Open       Date:  2021-03-18       Impact factor: 2.692

6.  Self-aligning prosthetic device for older patients with vascular-related amputations: protocol for a randomised feasibility study (the STEPFORWARD study).

Authors:  Natasha Mitchell; Elizabeth Coleman; Judith Watson; Kerry Bell; Catriona McDaid; Cleveland Barnett; Martin Twiste; Fergus Jepson; Abayomi Salawu; Dennis Harrison; Natalie Vanicek
Journal:  BMJ Open       Date:  2019-09-20       Impact factor: 2.692

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.