Long-term follow up of surgical repair of late bleb leaks after glaucoma filtering surgery.

Sami Al-Shahwan1, Abdullah A Al-Torbak, Ibrahim Al-Jadaan, Mamdouh Omran, Deepak P Edward.   

Abstract

PURPOSE: To study the long-term outcomes of surgical revision of leaking blebs after trabeculectomy and identify possible risk factors for failure. PATIENT AND METHODS: A retrospective, nonrandomized, noncomparative interventional study of 34 eyes with late bleb leaks after trabeculectomy that underwent bleb excision with conjunctival advancement. The primary outcome measure was successful repair and control of intraocular pressure (IOP). The other measures evaluated included change in visual acuity from baseline and complications such as recurrence of bleb leak, endophthalmitis or the need for additional antiglaucoma medication to control IOP.
RESULTS: After a mean follow up of 36.2+/-23 months, the mean IOP at the last visit was 14.5+/-7.6 mm Hg. IOP in 58.8% of eyes was controlled without medication. Complications included early leaks (7/34), late recurrent or persistent leaks (1/34), and endophthalmitis (1/34). In all, 41.2% patients required additional medication at the last visit. Survival analysis at 22 months the probability of total and qualified success was 52% and 72%, respectively. However, this dropped to 10% and 15%, respectively, at 5 years. The probability of total and qualified success further dropped to 2.5% and 5% at 5 years when the IOP cut-off was lowered from 21 to 15 mm Hg. Cox regression analysis failed to identify risk factors for bleb failure.
CONCLUSIONS: Surgical bleb revision seems to be effective in treating late bleb leaks with few postoperative complications. However, patients should be followed carefully as late failure of bleb function beyond 2 years is a significant possibility.

Entities:  

Mesh:

Year:  2006        PMID: 16988607     DOI: 10.1097/01.ijg.0000212257.02702.e8

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  10 in total

1.  Clinical and ASOCT evaluations of 'bleb-sparing epithelial exchange' in paediatric and adult dysfunctional blebs over 5 years.

Authors:  Ramanjit Sihota; Harathy Selvan; Talvir Sidhu; Neha Kamble; Dewang Angmo; Suresh Yadav; Tanuj Dada; Ashish Upadhyay
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-11-25       Impact factor: 3.117

2.  Aberrant wound-healing response in mitomycin C-treated leaking blebs: a histopathologic study.

Authors:  Victor M Elner; Paula Anne Newman-Casey; A Jayaprakash Patil; Andrew Flint; Jyotirmay Biswas; Sayoko E Moroi; Vaijayanthi Pushparaj; Deepak P Edward
Journal:  Arch Ophthalmol       Date:  2009-08

3.  MMP expression in leaking filtering blebs and tears after glaucoma filtering surgery.

Authors:  Nurit Mathalone; Sylvia Marmor; Michal A Rahat; Nitza Lahat; Yoram Oron; Orna Geyer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-03-31       Impact factor: 3.117

4.  A new manner of reporting pressure results after glaucoma surgery.

Authors:  Constantin-Dan Bordeianu; Cristina-Eugenia Ticu
Journal:  Clin Ophthalmol       Date:  2011-12-30

Review 5.  Innovations in glaucoma surgery from Dr. Rajendra Prasad Centre for Ophthalmic Sciences.

Authors:  Tanuj Dada; Neha Midha; Pooja Shah; Talvir Sidhu; Dewang Angmo; Ramanjit Sihota
Journal:  Indian J Ophthalmol       Date:  2017-02       Impact factor: 1.848

6.  Combined Phacoemulsification and Goniosynechialysis under an Endoscope for Chronic Primary Angle-Closure Glaucoma.

Authors:  Li Nie; Weihua Pan; Aiwu Fang; Zhangliang Li; Zhenbin Qian; Lin Fu; Yau Kei Chan
Journal:  J Ophthalmol       Date:  2018-02-08       Impact factor: 1.909

7.  Long-term outcomes of blebs repaired with scleral patch graft and conjunctival advancement in late-onset leak post-trabeculectomy.

Authors:  Vanita Pathak Ray; Swathi V Badakere
Journal:  Indian J Ophthalmol       Date:  2021-09       Impact factor: 1.848

8.  Commentary: Long term outcomes of blebs repaired with scleral patch graft and conjunctival advancement in late-onset leak post-trabeculectomy.

Authors:  Manju R Pillai
Journal:  Indian J Ophthalmol       Date:  2021-09       Impact factor: 1.848

9.  Surgical repair of leaking filtering blebs using two different techniques.

Authors:  António B Melo; M Reza Razeghinejad; Neal Palejwala; Jonathan S Myers; Marlene R Moster; George L Spaeth; L Jay Katz
Journal:  J Ophthalmic Vis Res       Date:  2012-10

10.  Point-of-service, quantitative analysis of ascorbic acid in aqueous humor for evaluating anterior globe integrity.

Authors:  Manas R Gartia; Santosh K Misra; Mao Ye; Aaron Schwartz-Duval; Lisa Plucinski; Xiangfei Zhou; David Kellner; Leanne T Labriola; Dipanjan Pan
Journal:  Sci Rep       Date:  2015-11-03       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.