Abstract

PURPOSE: The aim of this study was to improve the scanning peripheral anterior chamber depth analyzer (SPAC) for measuring anterior chamber depth (ACD), differentiating eyes with shallow anterior chamber, and automatically categorizing eyes into subgroups based on the ACD values. We also investigated its accuracy for measuring anterior ocular biometry.
MATERIALS AND METHODS: The improved SPAC system was equipped with an auto-focusing system for measuring ACD from the optical axis to the limbus without contacting the ocular surface, in addition to an auto-measuring system for determining central corneal thickness (CCT) and corneal radius of curvature (CRC). This system was also equipped with an auto-diagnosing program for differentiating eyes with narrow angle and an auto-classifying program for categorizing eyes into 12 subgroups according to the ACD values. A dummy eye was used for investigating the measurement accuracy and reproducibility of CCT, CRC, and ACD. Measurement duration and clinical availability were investigated using healthy subjects and glaucoma patients.
RESULTS: The SPAC-measured CCT, CRC, and ACD values were very similar to the theoretical values obtained from the dummy eye and their coefficients of variation were less than 1%. This system completed ACD measurement in 15.6+/-1.0 seconds and the mean coefficient of variation of ACD was 8.8+/-2.3%. The improved SPAC system successfully differentiated eyes with narrow angle from those with wide open angle.
CONCLUSIONS: The improved SPAC system can measure ACD easily with good accuracy and reproducibility, and is considered to be suitable for evaluating ACD in routine examinations and screening eyes with narrow angle.

Entities:  

Mesh:

Year:  2006        PMID: 16988600     DOI: 10.1097/01.ijg.0000212256.25573.44

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  4 in total

1.  Comparison of the anterior ocular segment measurements using swept-source optical coherent tomography and a scanning peripheral anterior chamber depth analyzer.

Authors:  Toshie Furuya; Fumihiko Mabuchi; Tatsuya Chiba; Satoshi Kogure; Shigeo Tsukahara; Kenji Kashiwagi
Journal:  Jpn J Ophthalmol       Date:  2011-08-10       Impact factor: 2.447

2.  Five-year incidence of angle closure among glaucoma health examination participants.

Authors:  Kenji Kashiwagi; Tatsuya Chiba; Fumihiko Mabuchi; Toshie Furuya; Shigeo Tsukahara
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-25       Impact factor: 3.117

3.  Changes in peripheral anterior chamber depth of a case of relapsing polychondritis with recurrent secondary angle closure glaucoma section sign.

Authors:  Kenji Kashiwagi; Toshie Furuya; Fumiko Kashiwagi
Journal:  Open Ophthalmol J       Date:  2008-01-04

4.  Longitudinal Change in Peripheral Anterior Chamber Depth of Eyes with Angle Closure after Laser Iridotomy.

Authors:  Toshie Furuya; Kenji Kashiwagi
Journal:  J Ophthalmol       Date:  2018-12-24       Impact factor: 1.909

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.