Literature DB >> 16988598

Long ciliary processes with no ciliary sulcus and appositional angle closure assessed by ultrasound biomicroscopy.

Lisandro Massanori Sakata1, Kenji Sakata, Remo Susanna, Viviane Mayumi Sakata, Marcelo Hatanaka, Luisa Trancoso, Julio Deleon Ortega, Roberto Freire Santiago Malta.   

Abstract

PURPOSE: Nonpupil block mechanisms and appositional angle closure after laser iridotomy (LI) have been reported as common findings in Asians. We evaluated the presence of these findings in a cohort of Brazilian patients using ultrasound biomicroscopy (UBM).
METHODS: This observational case-control study included 22 open angle eyes and 31 eyes with occludable angles on gonioscopy (defined by 2 examiners). UBM radial scans through a typical ciliary process were obtained in both light and dark conditions, at 6 and 12-o'clock positions. Long ciliary processes with no ciliary sulcus were determined on the basis of a reference line drawn perpendicular to the iris plane passing through a point located 750 mum from scleral spur. Trabecular ciliary processes distance was measured on 6-o'clock UBM images.
RESULTS: After LI, 52% of occludable angle eyes had appositional angle closure in both 6 and 12-o'clock UBM images. We also observed this finding in 14% and 23% of the control eyes (in 6 and 12-o'clock UBM images, respectively). A long ciliary process with no ciliary sulcus was observed in 61% of occludable angle eyes, and also in 32% of control eyes (6-o'clock UBM images). Control eyes had longer trabecular ciliary processes distance than occludable angle eyes (P<0.001).
CONCLUSIONS: The UBM finding of long ciliary processes associated with the absence of ciliary sulcus is not necessarily related to an anterior positioning of the ciliary processes. Whether UBM appositional angle closure after LI is associated with further angle closure process and/or poor intra-ocular pressure control remains to be evaluated.

Entities:  

Mesh:

Year:  2006        PMID: 16988598     DOI: 10.1097/01.ijg.0000212251.72207.19

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  4 in total

1.  Anterior-segment imaging for assessment of glaucoma.

Authors:  Roxana Ursea; Ronald H Silverman
Journal:  Expert Rev Ophthalmol       Date:  2010-02-01

2.  Plateau iris in Japanese patients with primary angle closure and primary angle closure glaucoma.

Authors:  Takanori Mizoguchi; Mineo Ozaki; Harumi Wakiyama; Nobuchika Ogino
Journal:  Clin Ophthalmol       Date:  2015-06-29

Review 3.  A review of the role of ultrasound biomicroscopy in glaucoma associated with rare diseases of the anterior segment.

Authors:  Giuseppe Mannino; Barmak Abdolrahimzadeh; Silvia Calafiore; Gianmario Anselmi; Cristina Mannino; Alessandro Lambiase
Journal:  Clin Ophthalmol       Date:  2016-07-29

4.  Prevalence of plateau iris configuration in primary angle closure glaucoma using ultrasound biomicroscopy in the Indian population.

Authors:  Gaurav Kumar; Shveta Jindal Bali; Anita Panda; Amit Sobti; Tanuj Dada
Journal:  Indian J Ophthalmol       Date:  2012 May-Jun       Impact factor: 1.848

  4 in total