Literature DB >> 16986985

Reliability of linear measurements on a virtual bilateral cleft lip and palate model.

Barbara C M Oosterkamp1, Wicher J van der Meer, Majelle Rutenfrans, Pieter U Dijkstra.   

Abstract

OBJECTIVE: To assess the reliability and validity of measurements performed on three-dimensional virtual models of neonatal bilateral cleft lip and palate patients, compared with measurements performed on plaster cast models.
MATERIALS AND METHODS: Ten high-quality plaster cast models of bilateral cleft lip and palate patients were scanned with an LDI-scanner to obtain a three-dimensional virtual model. Linear measurements were performed on the plaster cast models using a digital caliper and also on the three-dimensional virtual model using Viscam RP version 2.1 software. The measurements were performed by two observers on two occasions.
RESULTS: Intraclass correlations ranging from .81 to .96 were found for all measurements except the measurement between the constructed reference point pr and reference point i (intraclass correlation = .40). A post hoc procedure in which top-view screen prints of the three-dimensional virtual model were used to perform the measurement between reference points pr and i demonstrated an intraclass coefficient of .90.
CONCLUSIONS: Three-dimensional virtual models obtained by laser scanning neonatal cast models of bilateral cleft lip and palate patients can be used reliably and validly to perform linear measurements between existing reference points on the surface of the model using Viscam RP version 2.1 software. Measurements between reference points constructed outside the surface of the model cannot be validly performed on the three-dimensional virtual model with the software used in this study. For these measurements, top-view screen prints of the three-dimensional virtual model can be used.

Entities:  

Mesh:

Year:  2006        PMID: 16986985     DOI: 10.1597/05-078

Source DB:  PubMed          Journal:  Cleft Palate Craniofac J        ISSN: 1055-6656


  2 in total

1.  Comparison of the spatial landmark scatter of various 3D digitalization methods.

Authors:  Florian Boldt; Christian Weinzierl; Klaus Hertrich; Ursula Hirschfelder
Journal:  J Orofac Orthop       Date:  2009-05-31       Impact factor: 1.938

Review 2.  Linear measurements using virtual study models.

Authors:  Nghe S Luu; Liliya G Nikolcheva; Jean-Marc Retrouvey; Carlos Flores-Mir; Tarek El-Bialy; Jason P Carey; Paul W Major
Journal:  Angle Orthod       Date:  2012-04-24       Impact factor: 2.079

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.