Literature DB >> 16984788

Test of firefighter's turnout gear in hot and humid air exposure.

Ingvar Holmér1, Kalev Kuklane, Chuansi Gao.   

Abstract

Five students of a rescue training school cycled at 50 W for 20 min at 20 degrees C before walking at 5 km/hr up to 30 min in a climatic chamber at 55 degrees C and 30% relative humidity. 4 different types of clothing ensembles differing in terms of thickness and thermal insulation value were tested on separate days. All subjects completed 28-30 min in light clothing, but quit after 20-27 min in 3 firefighter ensembles due to a rectal temperature of 39.0 degrees C or subjective fatigue. No difference in the evolution of mean skin or rectal temperature was seen for the 3 turnout ensembles. Sweat production amounted to about 1000 g in the turnout gears of which less than 20% evaporated. It was concluded that the small differences between the turnout gears in terms of design, thickness and insulation value had no effect on the resulting heat physiological strain for the given experimental conditions.

Entities:  

Mesh:

Year:  2006        PMID: 16984788     DOI: 10.1080/10803548.2006.11076689

Source DB:  PubMed          Journal:  Int J Occup Saf Ergon        ISSN: 1080-3548


  5 in total

1.  Cooling vests with phase change materials: the effects of melting temperature on heat strain alleviation in an extremely hot environment.

Authors:  Chuansi Gao; Kalev Kuklane; Ingvar Holmér
Journal:  Eur J Appl Physiol       Date:  2010-12-03       Impact factor: 3.078

2.  Fractional Contribution of Wildland Firefighters' Personal Protective Equipment on Physiological Strain.

Authors:  Belén Carballo-Leyenda; José G Villa; Jorge López-Satué; Pilar S Collado; Jose A Rodríguez-Marroyo
Journal:  Front Physiol       Date:  2018-08-14       Impact factor: 4.566

3.  Comparison of the Impact of an Optimized Ice Cooling Vest and a Paraffin Cooling Vest on Physiological and Perceptual Strain.

Authors:  Mansoor Zare; Habibollah Dehghan; Saeid Yazdanirad; Amir Hossein Khoshakhlagh
Journal:  Saf Health Work       Date:  2019-01-19

4.  A novel vest with dual functions for firefighters: combined effects of body cooling and cold fluid ingestion on the alleviation of heat strain.

Authors:  Do-Hyung Kim; Gyu-Tae Bae; Joo-Young Lee
Journal:  Ind Health       Date:  2019-06-29       Impact factor: 2.179

5.  Impact of Different Personal Protective Clothing on Wildland Firefighters' Physiological Strain.

Authors:  Belén Carballo-Leyenda; José G Villa; Jorge López-Satué; Jose A Rodríguez-Marroyo
Journal:  Front Physiol       Date:  2017-08-24       Impact factor: 4.566

  5 in total