Literature DB >> 16982568

Monte Carlo characterization of target doses in stereotactic body radiation therapy (SBRT).

Premavathy Rassiah-Szegedi1, Bill J Salter, Clifton D Fuller, Melissa Blough, Niko Papanikolaou, Martin Fuss.   

Abstract

To compare finite-size pencil beam/equivalent path-length (FSPB/EPL) and Monte Carlo (MC) SBRT dose computations for serial tomotherapy and to quantitatively assess dose differences between the dose calculation methods. Based on 72 SBRT plans for pulmonary targets, FSPB/EPL, considering the inhomogeneous lung environment, and MC calculations were performed to establish differences between FSPB/EPL predicted dose and MC derived doses. Compared with MC, FSPB/EPL consistently overestimated minimum doses to the clinical target volume and planning target volumes by an average of 18.1+/-7.15% (range 4 to 33.4%), and 21.9+/-10.4% (range 1.2 to 45.5%), respectively. The respective mean target dose differences were 15.5+/-7.4% (2.8-36.4%) and 19.2+/-7.6% (3.6-40.1%). Deviations from MC doses were lesion size and location dependent, with smaller lesions completely embedded into lung parenchyma being most susceptible. Larger lesion in contact with mediastinum and chest wall showed lesser differences. In comparison with MC dose calculation, FSPB/EPL overestimates doses delivered to pulmonary SBRT targets. The observed dose differences may have impact on local tumor control rates, and may deserve consideration when using fast, but less accurate dose calculation methods.

Entities:  

Mesh:

Year:  2006        PMID: 16982568     DOI: 10.1080/02841860600919225

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  5 in total

1.  Stereotactic body radiation therapy for a new lung cancer arising after pneumonectomy: dosimetric evaluation and pulmonary toxicity.

Authors:  Alessandro Testolin; Maria Silvia Favretto; Stefania Cora; Carlo Cavedon
Journal:  Br J Radiol       Date:  2015-08-20       Impact factor: 3.039

2.  Evaluation of 4D dose to a moving target with Monte Carlo dose calculation in stereotactic body radiotherapy for lung cancer.

Authors:  Kiyotomo Matsugi; Mitsuhiro Nakamura; Yuki Miyabe; Chikako Yamauchi; Yukinori Matsuo; Takashi Mizowaki; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2012-12-18

3.  Clinical analysis of stereotactic body radiation therapy using extracranial gamma knife for patients with mainly bulky inoperable early stage non-small cell lung carcinoma.

Authors:  Dajun Wu; Hong Zhu; Hanjun Tang; Changlin Li; Feng Xu
Journal:  Radiat Oncol       Date:  2011-07-20       Impact factor: 3.481

4.  Adapted Prescription Dose for Monte Carlo Algorithm in Lung SBRT: Clinical Outcome on 205 Patients.

Authors:  Jean-Emmanuel Bibault; Xavier Mirabel; Thomas Lacornerie; Emmanuelle Tresch; Nick Reynaert; Eric Lartigau
Journal:  PLoS One       Date:  2015-07-24       Impact factor: 3.240

5.  Correlation of normal lung density changes with dose after stereotactic body radiotherapy (SBRT) for early stage lung cancer.

Authors:  Karine A Al Feghali; Qixue Charles Wu; Suneetha Devpura; Chang Liu; Ahmed I Ghanem; Ning Winston Wen; Munther Ajlouni; Michael J Simoff; Benjamin Movsas; Indrin J Chetty
Journal:  Clin Transl Radiat Oncol       Date:  2020-02-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.