Literature DB >> 16982272

Apical leakage of root-end placed SuperEBA, MTA, and Geristore restorations in human teeth previously stored in 10% formalin.

Michael R Pichardo1, Scott W George, Brian E Bergeron, Billie G Jeansonne, Rick Rutledge.   

Abstract

The purpose of this study was to determine if storage of extracted teeth in 10% formalin affects microleakage of MTA, Geristore, or SuperEBA root-end fillings. There were 130 freshly extracted single-rooted teeth collected, immediately placed in phosphate buffered saline (PBS) and stored for less than 24 hours. Teeth were divided and either placed in 10% formalin for a 4-weeks immersion or immediately prepared. Preparation for all teeth consisted of canal instrumentation, obturation, apical resection, retrograde preparation, and placement of a root-end filling material. After 72 hours, the apical portions were immersed in India ink under vacuum pressure for 30 minutes, and then stored in ink for 1 week. Negative controls and positive controls performed as expected. In general, there was significantly less dye leakage of root-end restorations in teeth stored in 10% formalin when compared to the freshly extracted teeth (p < 0.0001). No difference in dye leakage was observed between Geristore restorations placed in teeth stored in formalin as compared to fresh teeth (p = 0.892). Less dye leakage was noted in teeth restored with Geristore as compared to MTA and SuperEBA, regardless of storage medium (p < 0.0001). No difference was observed between MTA and SuperEBA root-end restorations (p = 0.157). The results of this study provide evidence that storage of teeth in 10% formalin over a 4-week period may significantly influence dye leakage as compared to leakage in freshly extracted teeth.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16982272     DOI: 10.1016/j.joen.2006.07.011

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  5 in total

1.  The comparison of MTA, Geristore® and Amalgam with or without Bioglass as a matrix in sealing the furcal perforations (in vitro study).

Authors:  Payman Mehrvarzfar; Afsaneh Dahi-Taleghani; Mohammad Ali Saghiri; Kasra Karamifar; Behnam Shababi; Ali Behnia
Journal:  Saudi Dent J       Date:  2010-04-18

2.  Comparative analysis of the effect of autoclaving and 10% formalin storage on extracted teeth: A microleakage evaluation.

Authors:  Kanika Attam; Sangeeta Talwar; Seema Yadav; Sanjay Miglani
Journal:  J Conserv Dent       Date:  2009-01

3.  Evaluation of Extrusion and Apical Seal of Thermafil™ Obturation with and without MTA as an Apical Barrier in Comparison with Lateral Condensation Technique: An In Vitro Study.

Authors:  Ajay S Rao; Rinku Mathur; Nimisha C Shah; Rajeshkrishna Malge; Sharanpriya Sathnoorkar; T Chandrasekhar
Journal:  Int J Clin Pediatr Dent       Date:  2020

4.  Evaluation of Apical Microleakage in Open Apex Teeth Using MTA Apical Plug in Different Sessions.

Authors:  Mohammad Yazdizadeh; Zeinab Bouzarjomehri; Navid Khalighinejad; Leyli Sadri
Journal:  ISRN Dent       Date:  2013-06-24

5.  The effect of protocol for disinfection of extracted teeth recommended by center for disease control (CDC) on microhardness of enamel and dentin.

Authors:  Amin Salem-Milani; Vahid Zand; Mohammad Asghari-Jafarabadi; Parvin Zakeri-Milani; Alireza Banifatemeh
Journal:  J Clin Exp Dent       Date:  2015-12-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.