Literature DB >> 16978314

An in vitro study of the compliance of paediatric tracheal tube cuffs and tracheal wall pressure.

V Bernet1, A Dullenkopf, V Cannizzaro, K Stutz, M Weiss.   

Abstract

Cuff volume-pressure curves and cuff pressure-tracheal wall pressure relationships were investigated in eight brands of currently available cuffed, paediatric tracheal tubes with internal diameters of 5.0 mm. Cuff volume-pressure curves were measured with the cuff unrestricted and with the cuff placed within a tracheal model with wall pressure measurements. With the tracheal tube cuffs, unrestricted cuff compliance at 20 cmH(2)O cuff pressure varied between 0.06 and 0.3 ml x cmH(2)O(-1). With the cuff restricted within the model trachea, all tracheal tube cuffs became considerably less compliant (0.01-0.09 ml x cmH(2)O(-1)). We found tracheal wall pressure was similar to the cuff pressure as long as the resulting cuff diameter was sufficiently large freely to drape the inner tracheal wall. We found that, regardless of whether a higher or lower compliant tube cuff was used, cuff hyperinflation uniformly resulted in potentially compromised tracheal mucosal blood flow; cuff pressure monitoring using cuff pressure limitation is therefore strongly recommended.

Mesh:

Year:  2006        PMID: 16978314     DOI: 10.1111/j.1365-2044.2006.04785.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  8 in total

1.  Recent advances in airway management in children.

Authors:  Francis Veyckemans
Journal:  F1000 Med Rep       Date:  2009-09-28

2.  Cuff overinflation and endotracheal tube obstruction: case report and experimental study.

Authors:  Christian Hofstetter; Bertram Scheller; Sandra Hoegl; Martin G Mack; Bernhard Zwissler; Christian Byhahn
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2010-04-08       Impact factor: 2.953

3.  [Clinical evaluation of a pressure release valve for paediatric cuffed tracheal tubes].

Authors:  S Fertl; V Bernet; A Schmitz; K Woitzek; M Weiss
Journal:  Anaesthesist       Date:  2009-01       Impact factor: 1.041

4.  An in vitro comparison of tracheostomy tube cuffs.

Authors:  Seamus Maguire; Frances Haury; Korinne Jew
Journal:  Med Devices (Auckl)       Date:  2015-04-21

5.  Effects of lubrication on air-sealing performance of a pediatric cuffed tracheal tube.

Authors:  Hiroko Nishioka; Yutaka Usuda; Go Hirabayashi; Koichi Maruyama; Tomio Andoh
Journal:  BMC Anesthesiol       Date:  2017-09-19       Impact factor: 2.217

6.  K-Y™ jelly inhibits increase in endotracheal tube cuff pressure during nitrous oxide exposure in vitro.

Authors:  Yukihide Koyama; Hiroyuki Oshika; Hiroko Nishioka; Naoko Kamoshida; Sousuke Tanaka; Gaku Inagawa; Tomio Andoh
Journal:  BMC Anesthesiol       Date:  2018-07-28       Impact factor: 2.217

7.  Effect of endotracheal tube lubrication on cuff pressure increase during nitrous oxide exposure: a laboratory and prospective randomized controlled trial.

Authors:  Moriyoshi Oji; Yukihide Koyama; Hiroyuki Oshika; Masashi Kohno; Yusuke Nakahashi; Sayano Fukushima; Hidemasa Iwakura; Tomio Andoh
Journal:  BMC Anesthesiol       Date:  2019-08-31       Impact factor: 2.217

8.  Assessing the accuracy of ultrasound measurements of tracheal diameter: an in vitro experimental study.

Authors:  Ran Ye; Feifei Cai; Chengnan Guo; Xiaocheng Zhang; Dan Yan; Chengshui Chen; Bin Chen
Journal:  BMC Anesthesiol       Date:  2021-06-24       Impact factor: 2.217

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.