Literature DB >> 16973669

Entrance surface doses to patients undergoing selected diagnostic X-ray examinations in Sudan.

I I Suliman1, N Abbas, F I Habbani.   

Abstract

The aim of the study was to evaluate the entrance surface doses (ESDs) to patients undergoing selected diagnostic X-ray examinations in major Sudanese hospitals. ESD per examination was estimated from X-ray tube output parameters in four hospitals comprising eight X-ray units and a sample of 346 radiographs. Hospital mean ESDs estimated range from 0.17 to 0.27 mGy for chest AP, 1.04-2.26 mGy for Skull AP/PA, 0.83-1.32 mGy for Skull LAT, 1.31-1.89 mGy for Pelvis AP, 1.46-3.33 mGy for Lumbar Spine AP and 2.9-9.9 mGy for Lumbar Spine LAT. With exception of chest PA examination at two hospitals, mean ESDs were found to be within the established international reference doses. The results are useful to national and professional organisations and can be used as a baseline upon which future dose measurements may be compared.

Entities:  

Mesh:

Year:  2006        PMID: 16973669     DOI: 10.1093/rpd/ncl137

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  Evaluation of dose-area product of common radiographic examinations towards establishing a preliminary diagnostic reference levels (PDRLs) in Southwestern Nigeria.

Authors:  Nnamdi N Jibiri; Christopher J Olowookere
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

2.  Survey of dose area product received by patients undergoing common radiological examinations in four centers in Nigeria.

Authors:  Bidemi I Akinlade; Idowu P Farai; Akintunde A Okunade
Journal:  J Appl Clin Med Phys       Date:  2012-07-05       Impact factor: 2.102

3.  Variation of Pediatric Doses Undergoing Digital and Computed Radiography Examination in Addis Ababa, Ethiopia.

Authors:  Seife Teferi; Daniel Zewdeneh
Journal:  Ethiop J Health Sci       Date:  2020-03

4.  Assessment of Pediatrics Radiation Dose from Routine X-Ray Examination at Jimma University Hospital, Southwest Ethiopia.

Authors:  Mesfin Zewdu; Elias Kadir; Melkamu Berhane
Journal:  Ethiop J Health Sci       Date:  2017-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.