A microplate solid scintillation counter as a radioactivity detector for high performance liquid chromatography in drug metabolism: validation and applications.

Gerard J Bruin1, Felix Waldmeier, K Olaf Boernsen, Ulrike Pfaar, Gerhard Gross, Markus Zollinger.   

Abstract

Sensitive radioactivity detection following high performance liquid chromatography (HPLC) separation remains a challenge in many drug metabolism studies with radiolabeled compounds. In this work, solid scintillation counting (SSC) after fraction collection into 96-well plates was evaluated as an off-line radioactivity detection method, in comparison with conventional liquid scintillation counting (LSC). The impact of counting time and biological matrix on the quantification of radiolabeled metabolites and parent drug in samples from animal and human absorption, distribution, metabolism and excretion (ADME) studies was investigated. Three different approaches were used to test whether reliable quantification by off-line SSC detection, which requires an approximately constant counting yield during the entire chromatographic run, can be realized: (i) the measurement of radioactivity-spiked biological blank samples without HPLC separation as an extreme case of biological background, (ii) the measurement of radioactivity-spiked HPLC fractions of biological blank samples and (iii) the comparison of radiochromatograms obtained by off-line SSC and LSC of real samples from ADME studies with radiolabeled compounds. Situations in which variations in SSC yield during an HPLC run are likely to lead to significant errors in quantitation were identified and are discussed. However, examples from a number of animal or human ADME studies showed that in the majority of cases off-line SSC provides very similar quantitative data, compared with the reference method of off-line LSC radioactivity detection. Approaches for validation of the off-line SSC approach in critical cases are discussed. The main advantages of off-line SSC, compared with off-line LSC, are lower detection limits and a substantially higher throughput. Several applications of off-line SSC detection in ADME studies are shown.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16970958     DOI: 10.1016/j.chroma.2006.08.020

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  A unique automation platform for measuring low level radioactivity in metabolite identification studies.

Authors:  Joel Krauser; Markus Walles; Thierry Wolf; Daniel Graf; Piet Swart
Journal:  PLoS One       Date:  2012-06-18       Impact factor: 3.240

2.  Separation and degradation detection of nanogram-per-litre concentrations of radiolabelled steroid hormones using combined liquid chromatography and flow scintillation analysis.

Authors:  Roman Lyubimenko; Bryce S Richards; Andrey Turshatov; Andrea I Schäfer
Journal:  Sci Rep       Date:  2020-04-27       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.