Literature DB >> 16970713

Accuracy of tissue Doppler echocardiography in the diagnosis of new-onset congestive heart failure in patients with levels of B-type natriuretic peptide in the midrange and normal left ventricular ejection fraction.

Stephane Arques1, Emmanuel Roux, Pascal Sbragia, Bertrand Pieri, Richard Gelisse, Pierre Ambrosi, Roger Luccioni.   

Abstract

BACKGROUND: Based on the hypothesis that it reflects left ventricular (LV) diastolic pressures, B-type natriuretic peptide (BNP) is largely utilized as first-line diagnostic complement in the emergency diagnosis of congestive heart failure (HF). The incremental diagnostic value of tissue Doppler echocardiography, a reliable noninvasive estimate of LV filling pressures, has been reported in patients with preserved LV ejection fraction and discrepancy between BNP levels and the clinical judgment, however, its clinical validity in such patients in the presence of BNP concentrations in the midrange, which may reflect intermediate, nondiagnostic levels of LV filling pressures, is unknown.
METHODS: 34 patients without history of HF, presenting with acute dyspnea at rest, BNP levels of 100-400 pg/ml and normal LV ejection fraction were prospectively enrolled (17 with congestive HF and 17 with noncardiac cause). Tissue Doppler echocardiography was performed within 3 hours after admission.
RESULTS: Unlike BNP (P = 0.78), Boston criteria (P = 0.0129), radiographic pulmonary edema (P = 0.0036) and average E/Ea ratio (P = 0.0032) were predictive of congestive HF by logistic regression analysis. In this clinical setting, radiographic pulmonary edema had a positive predictive value of 80% in the diagnosis of congestive HF. In patients without evidence of radiographic pulmonary edema, average E/Ea > 10 was a powerful predictor of congestive HF (area under the ROC curve of 0.886, P < 0.001, sensitivity 100% and specificity 78.6%).
CONCLUSION: By better reflecting LV filling pressures, bedside tissue Doppler echocardiography accurately differentiates congestive HF from noncardiac cause in dyspneic patients with intermediate, nondiagnostic BNP levels and normal LV ejection fraction.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16970713     DOI: 10.1111/j.1540-8175.2006.00281.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  3 in total

1.  The role of imaging in the management of cardiorenal syndrome.

Authors:  Sajid Melvin George; Kambiz Kalantarinia
Journal:  Int J Nephrol       Date:  2011-01-24

Review 2.  Current clinical applications of spectral tissue Doppler echocardiography (E/E' ratio) as a noninvasive surrogate for left ventricular diastolic pressures in the diagnosis of heart failure with preserved left ventricular systolic function.

Authors:  Stephane Arques; Emmanuel Roux; Roger Luccioni
Journal:  Cardiovasc Ultrasound       Date:  2007-03-26       Impact factor: 2.062

3.  Estimation of Diastolic Filling Pressure with Cardiac CT in Comparison with Echocardiography Using Tissue Doppler Imaging: Determination of Optimal CT Reconstruction Parameters.

Authors:  Ji-Sun Hwang; Heon Lee; Bora Lee; Soo-Jeong Lee; Sung Shick Jou; Hyun Kyung Lim; Jon Suh
Journal:  Korean J Radiol       Date:  2017-05-19       Impact factor: 3.500

  3 in total