Literature DB >> 16970343

Development and evaluation of a candidate reference measurement procedure for the determination of progesterone in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry.

Susan S-C Tai1, Bei Xu, Michael J Welch.   

Abstract

Progesterone is a steroid hormone that is involved in regulating female reproductive processes. Its concentration in blood is measured to determine ovarian function. A candidate reference measurement procedure for progesterone in human serum involving isotope dilution coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. The progesterone along with its internal standard (progesterone-13C2) was extracted from the serum matrix using liquid-liquid extraction prior to reversed-phase LC/MS/MS. The accuracy of the measurement was evaluated by a comparison of results of this method on a lyophilized human serum reference material for progesterone [Certified Reference Material (CRM) 347] with the certified values determined by gas chromatography/mass spectrometry (GC/MS) reference methods and by a recovery study for the added progesterone. The results of this method for progesterone agreed with the certified value within the uncertainty of the measurements for the CRM 347. The recovery of the added progesterone ranged from 100.1 to 100.9%. This method was applied to the determination of progesterone in frozen serum samples from three individual female donors with the progesterone concentrations ranging from 0.151 to 24.42 ng/g. Excellent reproducibility was obtained with within-set coefficients of variation (CVs) ranging from 0.1 to 1.4%, and between-set CVs ranging from 0.3 to 0.5%. Excellent linearity was also obtained with correlation coefficients of all linear regression lines (measured intensity ratios vs mass ratios) ranging from 0.9998 to 1.0000. The detection limit at a signal-to-noise ratio of approximately 3 was 1.8 pg of progesterone. This well-characterized LC/MS/MS method for serum progesterone, which demonstrates good accuracy and precision, low susceptibility to interferences, and comparability with GC/MS reference methods, qualifies as a reference measurement procedure that can be used to provide an accuracy base to which routine methods for progesterone can be compared and that will serve as a standard of higher order for measurement traceability.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16970343     DOI: 10.1021/ac060936b

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry.

Authors:  Susan S-C Tai; Mary Bedner; Karen W Phinney
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

2.  Gold nanoparticles as assisted matrices for the detection of biomolecules in a high-salt solution through laser desorption/ionization mass spectrometry.

Authors:  Hsin-Pin Wu; Cheng-Ju Yu; Chin-Yu Lin; Yen-Hsiu Lin; Wei-Lung Tseng
Journal:  J Am Soc Mass Spectrom       Date:  2009-01-09       Impact factor: 3.109

3.  Role of CYP2A5 in the clearance of nicotine and cotinine: insights from studies on a Cyp2a5-null mouse model.

Authors:  Xin Zhou; Xiaoliang Zhuo; Fang Xie; Kerri Kluetzman; Yue-Zhong Shu; W Griffith Humphreys; Xinxin Ding
Journal:  J Pharmacol Exp Ther       Date:  2009-11-18       Impact factor: 4.030

4.  Development of a multi-class steroid hormone screening method using Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS).

Authors:  Ashley S P Boggs; John A Bowden; Thomas M Galligan; Louis J Guillette; John R Kucklick
Journal:  Anal Bioanal Chem       Date:  2016-04-02       Impact factor: 4.142

5.  LC-MS/MS Method for Rapid Quantification of Progesterone in Rabbit Plasma and Its Application in a Pharmacokinetic Study of the Transdermal Formulation.

Authors:  Cao-Son Tran; Quang-Dong Bui; Ngoc-Tho Thi Nguyen; Minh-Hanh Dao; Thach-Tung Nguyen
Journal:  J Anal Methods Chem       Date:  2020-10-30       Impact factor: 2.193

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.