Literature DB >> 16970339

Antibody microarray detection of Escherichia coli O157:H7: Quantification, assay limitations, and capture efficiency.

Andrew G Gehring1, David M Albin, Arun K Bhunia, Sue A Reed, Shu-I Tu, Joseph Uknalis.   

Abstract

A sandwich fluorescent immunoassay in a microarray format was used to capture and detect E. coli O157:H7. Here, we explored quantitative aspects, limitations, and capture efficiency of the assay. When biotinylated capture antibodies were used, the signal generated was higher (over 5-fold higher with some cell concentrations) compared to biotinylated protein G-bound capture antibodies. By adjusting the concentration of reporter antibody, a linear fluorescent response was observed from approximately 3.0 x 10(6) to approximately 9.0 x 10(7) cells/mL, and this was in agreement with the number of captured bacteria as determined by fluorescence microscopy. Capture efficiency calculations revealed that, as the number of bacteria presented for capture decreased, capture efficiency increased to near 35%. Optimization experiments, with several combinations of capture and reporter antibodies, demonstrated that the amount of bacteria available for capture (10(6) versus 10(8) cells/mL) affected the optimal combination. The findings presented here indicate that antibody microarrays, when used in sandwich assay format, may be effectively used to capture and detect E. coli O157:H7.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16970339     DOI: 10.1021/ac0608467

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  11 in total

1.  Multiplexed detection of bacteria and toxins using a microflow cytometer.

Authors:  Jason S Kim; George P Anderson; Jeffrey S Erickson; Joel P Golden; Mansoor Nasir; Frances S Ligler
Journal:  Anal Chem       Date:  2009-07-01       Impact factor: 6.986

Review 2.  Protein microarrays and biomarkers of infectious disease.

Authors:  Mohan Natesan; Robert G Ulrich
Journal:  Int J Mol Sci       Date:  2010-12-16       Impact factor: 5.923

3.  Antibody-based sensors: principles, problems and potential for detection of pathogens and associated toxins.

Authors:  Barry Byrne; Edwina Stack; Niamh Gilmartin; Richard O'Kennedy
Journal:  Sensors (Basel)       Date:  2009-06-05       Impact factor: 3.576

4.  Apparent thixotropic properties of saline/glycerol drops with biotinylated antibodies on streptavidin-coated glass slides: implications for bacterial capture on antibody microarrays.

Authors:  David M Albin; Andrew G Gehring; Sue A Reed; Shu-I Tu
Journal:  Sensors (Basel)       Date:  2009-02-16       Impact factor: 3.576

5.  Antibody Microarray for E. coli O157:H7 and Shiga Toxin in Microtiter Plates.

Authors:  Andrew G Gehring; Jeffrey D Brewster; Yiping He; Peter L Irwin; George C Paoli; Tawana Simons; Shu-I Tu; Joseph Uknalis
Journal:  Sensors (Basel)       Date:  2015-12-04       Impact factor: 3.576

6.  A Label-Free Impedance Immunosensor Using Screen-Printed Interdigitated Electrodes and Magnetic Nanobeads for the Detection of E. coli O157:H7.

Authors:  Ronghui Wang; Jacob Lum; Zach Callaway; Jianhan Lin; Walter Bottje; Yanbin Li
Journal:  Biosensors (Basel)       Date:  2015-12-15

Review 7.  Microarray Strategies for Exploring Bacterial Surface Glycans and Their Interactions With Glycan-Binding Proteins.

Authors:  María Asunción Campanero-Rhodes; Angelina Sa Palma; Margarita Menéndez; Dolores Solís
Journal:  Front Microbiol       Date:  2020-01-10       Impact factor: 5.640

8.  A high-throughput antibody-based microarray typing platform.

Authors:  Andrew Gehring; Charles Barnett; Ted Chu; Chitrita DebRoy; Doris D'Souza; Shannon Eaker; Pina Fratamico; Barbara Gillespie; Narasimha Hegde; Kevin Jones; Jun Lin; Stephen Oliver; George Paoli; Ashan Perera; Joseph Uknalis
Journal:  Sensors (Basel)       Date:  2013-05-03       Impact factor: 3.576

9.  Novel platform development using an assembly of carbon nanotube, nanogold and immobilized RNA capture element towards rapid, selective sensing of bacteria.

Authors:  Elizabeth I Maurer; Kristen K Comfort; Saber M Hussain; John J Schlager; Sharmila M Mukhopadhyay
Journal:  Sensors (Basel)       Date:  2012-06-12       Impact factor: 3.576

Review 10.  Automated analytical microarrays: a critical review.

Authors:  Michael Seidel; Reinhard Niessner
Journal:  Anal Bioanal Chem       Date:  2008-05-27       Impact factor: 4.142

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.